21 Results of the computational program and the limits of inference

Eudgene Brenev (human author) · Mira Veyran (AI coauthor · AI persona) · info@brenev.com

Contents
  1. 01 Front matter
  2. 02 Preface
  3. 03 Contents
  4. 04 1 What quantum theory claims
  5. 05 2 States and probabilities in quantum dynamics
  6. 06 3 Measurement and environment
  7. 07 4 Entanglement and limitations on explanation
  8. 08 5 When a hypothesis changes a theory
  9. 09 6 How measurement becomes evidence
  10. 10 7 How to find the superposition limit
  11. 11 8 Objective collapse models
  12. 12 9 Environment as a physical model
  13. 13 10 Three measurements and the limits of their meaning
  14. 14 11 What heating and correlations add
  15. 15 12 From raw counts to a verified result
  16. 16 13 Why gravity is difficult to include in the quantum picture
  17. 17 14 Two masses and a test of the mediator
  18. 18 15 What does quantum time mean?
  19. 19 16 How to compare gravity models
  20. 20 17 Universal spatial noise hypothesis
  21. 21 18 Memory and controlled decoherence hypothesis
  22. 22 19 The limit of distinguishability and a minimal set of observations
  23. 23 20 Experimental apparatus and the full data pipeline
  24. 24 21 Results of the computational program and the limits of inference
  25. 25 What has been established and where inference ends
  26. 26 Appendix A Symbols and physical units
  27. 27 Appendix B A concise glossary
  28. 28 Appendix C Reproducing the calculations
  29. 29 Appendix D Technical derivations
  30. 30 References
  31. 31 List of figures
Text size

21 Results of the computational program and the limits of inference

The program ends with the results of several different tests: reproducing the known experiment, analyzing artificial initiating events, testing an erroneous background, and calculating the final control. Each result has its own area of ​​applicability. Their comparison shows what has already been established within the models and which statements will require new observations.

What belongs to literature and what is done here

The book combines existing physical models and inference methods into a reproducible sequence of calculations. The historical priority of CSL, dynamic decoupling, multiqubit noise spectroscopy, and statistical tests does not carry over to this sequence. The scientific contribution of a particular new protocol is determined by the difference between its premises and results from the closest published works, and not by the number of combined directions.

Important immediate predecessors of the statistical part are the studies of Schrinski and co-authors 2019 and 2020 years [65, 66]. They use original measurements and their uncertainties to test parameterized modifications of quantum mechanics. The work of Laing and Bateman examines Bayesian inference and experimental control selection in near-field interferometry with background mechanisms [19]. The idea of ​​inferring events or taking pressure into account is therefore not a new result of this book.

The actual completed part here has an educational and methodological status: a fully reproducible binomial protocol is defined, independent error ensembles are performed, transfer to delayed distances is shown, the influence of finite impulses is calculated, and a counterexample of erroneous physical attribution is presented. The resulting numbers refer to explicitly specified models. They are not stated for the first time by discovered laws, universal limits of nature, or experimental detection of collapse.

The comparison table shows the place of the given calculations among existing methods. To establish a new scientific result, it is necessary to prove the superiority of a specific protocol over the closest method with the same physical resources or to identify a previously unknown limit of distinguishability. The methodological conclusions presented here are supported by calculations and tests of their applicability.

Immediate predecessors and status of completed work

Support work

An established result

Use in the book

Schrinski et al. 2019 [65]

Conclusion based on input data and uncertainties

Basis of event analysis; separate frequency simulation of own training protocol

Schrinski et al. 2020 [66]

Testing modifications in matter wave interference

Distinguishing between a model limitation and a general claim of classicality

Laing and Bateman 2024 [19]

Bayesian background analysis and control selection

A reference point for physical completeness; Calculation of conditional KL for four instructional designs

Arenz et al. 2015 [47]

Dynamic decoupling in testing alternative theories

Explicit refinement of final control and false remainder

Paz-Silva et al. 2017 [50]

Multiqubit Gaussian noise spectroscopy

Particular two-sensor example with specified probabilities

Green and others 2013 [67]

Freeform control and universal noise

Numerical propagation of a specific rectangular pulse

Reproduced bounds and independent calculations

The calculation program begins with checking the control limits. The spatial kernel reproduces the compact limit and disappears at zero separation. The three-point contrast eliminates the stated constant and quadratic background terms, and its generalization to linear separation and convergence changes the optimal distance. Analytical Ramsey and echo coincide with independent integration and with the instantaneous full propagation limit of the controlled sensor.

For the stochastic time model, the convergence of the Hermite expansion was additionally verified. For the gravitational example, the state matrix, partial transposition spectrum, and analytical threshold are compared. For the statistical part, the original binomial samples and complete selection results are saved. Such tests do not prove the truth of physical hypotheses, but they allow us to eliminate a number of errors in normalization, indices and software implementation.

External replication uses published data and the author's analysis presented in chapter 12: 95 scans, 3895 positions and 10 772 714 registered counts. With the initial fixed calibrations and spatial scale ℏ/σq = 10 nm, we obtained τ₅ = 2.842065516·10¹⁵ s and μ = 15.453634, which reproduces the published rounded values. Independent trapezoidal quantile interpolation gives μ = 15.451403. The difference around 0.00223 is less than the rounding accuracy given in the article. This is a repetition of the stated procedure and not a new blind analysis of all systematic effects; this part's own simulations have separate assumptions and calibrations.

Full procedure error rate

For the spatial experiment, the likelihood ratio statistics q = 2(ℓ₁ − ℓ₀) was applied. In the alternative, A is non-negative and iterates over the entire predefined mesh rC; at zero A = 0. If zero, the length is not determined from the data. Therefore, the threshold is taken from a separate null ensemble that has undergone the same selection and search, and not from the usual formula for one internal parameter.

The first ensemble of 1000 sets calibrates the 95th percentile: qcrit = 3.48640. The second independent null ensemble yielded 56 exceedances from 1000. The false discovery rate is 5.6%; The 95 Wilson percentage interval for the Monte Carlo estimate is 4.3 %–7.2 %. The difference from the nominal 5% is within the final test statistics. The threshold itself is also estimated from the final ensemble; the specified interval is conditional on its realized value.

When A = 0.12 was introduced s⁻¹, the procedure detected an addition in 1000 cases from 1000. Zero number of gaps in this series does not mean mathematically unity power: the lower limit of the Wilson interval is 99.62%. For the weaker A = 0.035 s⁻¹, 841 out of 1000 was found, that is, 84.1% with the interval 81.7%–86.2%. This gives rise to the quantitative meaning of sensitivity: the same protocol has a different probability of success at different amplitudes.

The profile area along A has a separate calibration. With A = 0.12 s⁻¹ and a given background 1000 of simulations, the threshold 4.26806 for the profile difference was determined. At the next independent thousand, the true value entered the region 946 times. The actual coverage is 94.6%; Monte Carlo assessment interval is 93.0 %–95.8 %. This is a test at one internal point, and not a proof of coverage on the entire boundary A = 0 and throughout the entire continuous space.

The calibration follows recording fluctuations and joint background estimation. It does not repeat the unknown history of a real device: geometric drift, temperature unsteadiness and incorrect physical transfer function cannot be considered automatically taken into account here. For other equipment, the threshold must be calculated according to its own model and range of systematic effects. The finite grid rC is also included in the protocol definition; changing this grid changes the number of available explanations for random variation.

Six ensembles of 1000 sets, as well as a separate demo set, are saved along with the code. Separate null and signal ensembles are used for thresholding, error rate testing, and coverage testing. This excludes quality assessment on the same samples for which the rule was configured. The generator and assay are intentionally identical in control runs; the next episode violates precisely this convenient condition.

Testing on independent ensembles using 1000 sets

Check

Frequency

95 % interval Monte Carlo

False detection with a given background

5.6 %

4,3 %–7,2 %

Detection A = 0.035 s⁻¹

84.1 %

81,7 %–86,2 %

Detection A = 0.12 s⁻¹

100.0 %

99,62 %–100,00 %

Coverage A = 0.12 s⁻¹

94.6 %

93,0 %–95,8 %

The intervals describe the final precision of the Monte Carlo estimate. They are not confidence intervals for the physical parameters of the experiment.

Cumulative distributions of likelihood ratio statistics for three scenarios and the vertical line of the calibrated threshold.

Figure 60. Distributions of full search statistics by scale: given background, weak and strong additives. The threshold is determined by a separate null ensemble. Each validation curve contains 1000 of complete synthetic experiments.

Checking against a background not included in the fit

In the last series, the fundamental amplitude A is zero, but the environment creates two components of random impulses. Their spatial scales are 0.65ℓ and 2.2ℓ, non-negative weights are 0.65 and 0.35; the total amplitude is 0.12 s⁻¹. A mixture of admissible Gaussian impulse processes remains an admissible process. It is not equal to the only Gaussian kernel, which is used in the analyzing alternative, and certainly not included in its quadratic zero background.

However, the same procedure exceeds the previous threshold in 1000 cases from 1000. This is not an error in calculating p in the written null model: that model is indeed incorrect for the new generator. It would be a mistake to call all excesses a detection of objective collapse. There is no such mechanism in the generator. The result only establishes the insufficiency of the limited background family and the preference for a more flexible form of attenuation.

An even stronger counterexample can be constructed. If the medium is allowed exactly the same Gaussian momentum kernel with the same mass law, its ensemble generator will coincide with the localization dynamics being tested. The predictions of all available system sequences then match, including additional replicates and energy observations, if the match covers the full generator. The minimum KL distance is zero. In this case, the problem is not solved by increasing the number of events or by a smarter optimizer.

The output is possible only after adding physical information for which the models diverge: an independent observation of the medium, a verified limitation of its spectrum, a different law depending on geometry, or a new recording channel. Such a limitation cannot be declared established simply because it is convenient for obtaining sensitivity. Therefore, a positive statistical discovery in the book is formulated as a disagreement with a given background, and the question of fundamental origin remains conditional on the completeness of physical alternatives.

Selecting measurements with consistent discriminability

The design of the next series begins with a given area of interest. It may include specific non-null hypothesis parameters or a range that is not already excluded by other data. Experimental options are compared under the same time budget and taking into account the actual outcome of events. An increase in complexity is justified if it adds independent information or reduces major uncertainty, and not just increases the absolute value of the ideal contrast.

One possible criterion is the minimum difference in probabilistic predictions for all acceptable background options. In the formula below, the setting q denotes the full protocol, θ* the fixed non-null hypothesis being tested, and η0 and η1 the environment parameters. The Kullback-Leibler divergence between the distributions of possible data was used. This is a measurement selection instrument; the mathematical measure itself is not a new physical entity.

If the achieved minimum is zero, there are indistinguishable predictions among the feasible options. This protocol does not ensure uniform discrimination between the selected models. If the infimum only approaches zero, it is necessary to study the limiting region separately. When searching across a range of fundamental parameters, one cannot imperceptibly include zero intensity and then expect positive guaranteed sensitivity to the entire range: at the very zero boundary, the compared models coincide.

Δ(q;θ*)=infη0∈N0,η1∈N1DKLPq(·∣θ*,η1)‖Pq(·∣H0,η0).

(21.1) An example of a criterion for stable discrimination with a fixed non-zero hypothesis being tested. The sets of acceptable backgrounds are specified by independent calibration. The criterion should be weighed against the cost and duration of the chosen protocol.

Four designs with the same number of events

The minimum KL-distance criterion was calculated for four pre-listed protocols. All have 5000 calibration and 25 600 main events; the distances and distribution of main events between them change. The fixed non-null hypothesis has A = 0.12 s⁻¹ and rC = ℓ. The null model contains only a constant and quadratic background. In both hypotheses, five parameters of readout and normal attenuation are varied separately.

The main design range is specified in coordinates (a,b₀₁,B₂₁,b₀₂,B₂₂): [0.040;0.065], [0.025;0.065], [0.22;0.36], [0.040;0.085], [0.35;0.52]. These are clearly accepted ranges for training calculations. They are not presented as measured constraints of a particular laboratory. In a real experiment project they would have to be justified by independent calibration. After this, joint numerical minimization is performed based on the background of both hypotheses. Each minimum is tested against six different starting points.

Among the four candidates, the “Emphasis on curvature” option had the largest minimum distance. Its value is 45.334. The wide uniform protocol gave 41.274, and the restriction to short splits only gave 7.627. This is the result of a choice within a finite set for a specific budget, and not a proof of the absolute optimum over all possible controls.

In the version with an emphasis on curvature, the distances are 0; 0.6; 1.3; 2.0; 2.8; 4.0; 6.0 in units of ℓ. 1400 is allocated to them accordingly; 1200; 1800; 2200; 2000; 1800; 2400 events per object. The zero point limits the base visibility, intermediate distances distinguish core bending, and long distances limit quadratic background and saturation. Therefore, the utility distribution does not coincide with the choice of a single point of maximum absolute contrast.

The price of calibration assumptions is tested by expanding the ranges to [0.03;0.09], [0;0.15], [0;0.8], [0;0.15], [0;1.0]. Minimum distances are reduced as the normal background has more ways to simulate the signal. The table shows this change for each design. When an accurate noise simulation is included in the background, the distance becomes zero for all options. This is a separate qualitative limit that cannot be overcome by successful redistribution of the same budget.

KL is the expected log-likelihood difference for given distributions, but its number is not equal to the p-value and is not automatically translated into a number of standard deviations here. The behavior of the full procedure on finite samples is tested for a wide protocol at one nominal point; this is not a test of the power under the worst-case background found by KL minimization. To finally select a new design, it is necessary to repeat these checks with its threshold, calibration and real losses. The performed minimization provides a reasonable design rating and does not replace experimental validation.

An equal budget in this comparison means an equal number of events recorded. If receiving a large split increases preparation time or reduces output, you should replace the event limit with a total time limit. Without such a transfer model, the promise of gains in operating hours would be unfounded. Therefore, the results presented strictly retain the resource meaning that was specified during the calculation.

Numerical selection among four valid designs

Design

Events

Minimum KL

After expanding the background

Short separations

30600

7.627

0.810

Wide range

30600

41.274

15.058

Emphasis on curvature

30600

45.334

17.167

Focus on saturation

30600

39.933

15.709

The minima are obtained numerically with several starting points; this is not a proof of the global optimality of continuous control.

The four columns compare the least favorable discriminability of short, wide, curvature- and saturation-oriented geometries.

Figure 61. Numerical minimum KL distance of four protocols with the same budget 30 600 of registered events and a limited design background range. The columns compare only the listed options; KL is not a p-value.

Separate the search series from the confirming series

A search series is needed to study the device, detect unknown interference and select an adequate model. It allows changes to hypotheses if their origin is documented. The confirmatory series has a different task: to verify an already recorded prediction. Before opening it, the protocol, range of parameters, processing method, control observations and conditions for recognizing the result as inconsistent with the model are recorded.

The independence of confirmation is enhanced when the physical regime changes. A prediction for a different mass or shape provides more information about universality than additional repetitions of the former object. Predicting a new sequence tests the temporal model. Playback on another installation experiences transfer beyond the specific environment. Neither of these options guarantees a fundamental discovery, but each closes off some possibility of attributing the result to a local feature.

An unexpected observation retains value even if it fails a predetermined criterion. It can be used to build the next version of the hypothesis. In this case, the result is honestly returned to the search phase. Such a discipline does not prohibit creativity: it makes a distinction between the moment an idea emerges and the moment when an idea first stands up to independent scrutiny.

Formal reasons to reject the hypothesis version

The spatial version is rejected when its fixed kernel and mass relation law do not describe the intended observations under any acceptable general parameters, and the joint verification procedure takes into account errors and multiple comparisons. The time-based single-exponential version is rejected when it does not predict delayed control sequences within reasonable uncertainties. These findings apply to specific versions and not to all possible additional processes.

The proposed detection method may also fail regardless of the truth of the physical hypothesis. If the addition of a valid background mechanism makes the signal precisely unidentifiable, the claim that this set of observations establishes its origin should be abandoned. If the required calibration accuracy is not available on the selected platform, this protocol is deferred. If a computational implementation violates the positivity of a state or unit, the model is first corrected and any bounds derived from the error are invalidated.

Avoiding generality is especially important when transferring between systems. If different platforms require incompatible fundamental parameters after a thorough environment check, you cannot enter a different intensity for each and keep the same name of the hypothesis. A new dependence law can be proposed, but it becomes a new version with its own predictions. It'll need another independent series, not a recycle of previous successes.

Result with or without residual effect

The absence of a significant additional signal leads to parameter limitations. It is necessary to publish the area of ​​scale in which the experiment is truly sensitive, and the conditions on which the boundary is based. A family with arbitrarily weak intensity usually maintains an almost standard limit. Therefore, the formulation of the result must distinguish between exclusion of a specific area and evidence of the absence of any possible deviation.

If a residual is present, alternative explanations and the dependence of the conclusion on the model are first tested. The predicted spatial profile, temporal structure, and interobject transport are then examined. Strong evidence requires agreement between these parts, not just a small error of one amplitude. Particularly valuable is a result that links two different observations in advance and withstands their joint testing without adding free parameters.

If the remainder disappears after improving the description of the environment, the research does not lose its meaning. The real mechanism was identified, the installation model was corrected, and the conditions for future tests were clarified. This outcome should be retained in the final report, rather than leaving only the last successful curve. A history of excluded explanations helps other groups avoid making the same mistake.

Branched map of conclusions: conditional boundaries without a signal, refinement of the device with an explained remainder, a new observable with indistinguishability, and version support with a consistent transfer.

Figure 62. The absence of an additional signal provides a conditional limitation of the parameters in the sensitive area of ​​the experiment. The remainder guides the investigation toward a model of the environment, independent tests, and prespecified transfer. The background explanation clarifies the device; exact indiscernibility requires another observable; a consistent migration supports a specific version only within the tested range. Neither exceeding a statistical threshold nor a small p-value by itself leads to the discovery of collapse. If a surprise is used to change the model, it is checked by the next independent series.

Completed result and next scientific task

The computer program produced several results of different nature. The published interference analysis is reproduced on external data. The illustrative spatial experiment is advanced from binary outcomes to overall parameter estimation, verified false discovery rates, and prediction of new conditions. A temporal example quantifies how finite control and registration error create a spurious white component. The gravity part relates the ideal phase to the noise threshold and measurable evidence.

There is also a negative result that determines the strength of any positive statements: expansion of the admissible background can destroy physical identification, even when the statistical test confidently rejects the original background. Exact imitation results in channel matching and zero discriminability; the approximate mixture of noise scales shows the fragility of the narrow model on finite data. Both cases are retained in the final set because they limit the meaning of the discovered remainder.

The next independent scientific task should be set in relation to these results. For example, one can look for a measurable constraint in the surrounding field that precludes exact simulation and yet is tested independently of the signal being sought. Another option is to extend full statistical calibration to a continuous range of scales and experimentally established class of systematic effects. Each direction will require its own result and comparison with the literature; completeness of educational calculations does not replace evidence of scientific novelty.

The book thereby brings research logic to an executable procedure. Its outcome is not the promise of necessarily discovering new physics, but the ability to say in advance what distinguishes the chosen experiment, how often the analysis is wrong, and what additional observations might make the conclusion stronger. It is precisely this accuracy that makes further work cumulative: the following result is based on the reproduced calculation and the known limit of its applicability.

A physical inference becomes stronger when its numerical sensitivity and limit are known. In this program, both elements are presented together: completed checks are adjacent to obvious counterexamples of indistinguishability. Further expansion of quantum theory must maintain the same connection between formula, measurement, alternative and independent prediction.

Cite this edition

Available here since: . Mira Veyran is an AI coauthor.