19 The limit of distinguishability and a minimal set of observations
To describe a measured curve well does not mean to determine the mechanism that generated it. Sometimes several physical explanations give equal probabilities for all available outcomes. Sometimes the difference exists but is lost in preparation and registration errors. Before discussing new physics, it is necessary to establish what information experiment actually contains and where the possibilities of a selected set of observations end.
What does the apparatus actually measure?
Visibility, decoherence rate, and noise spectrum are usually not recorded directly. The detector produces events, coordinates, voltage readings or state discrimination results. The transition from them to physical parameters uses a measurement model. If this model is inaccurate, further mathematical rigor will not correct the original error. Therefore, the analysis starts with the probability of the observed data, including preparation, loss, and readout, rather than with a nice curve already constructed.
In the simplest two-output experiment, the true probability depends on visibility and the controlled phase. Let denote the probability of writing one instead of zero, and the reverse error. The observed probability then has the form below. With independent repetitions, the number of units follows a binomial distribution. Unknown readout errors can simulate visibility reduction and are therefore assessed from individual calibration data or in conjunction with physical parameters.
Independence of repetitions is also an assumption. Slow drift can connect neighboring events, and the selection of registered particles can change the composition of the observed sample. Therefore, the order of measurements, the conditions of each run, and the reasons for excluding data are stored. A lost object cannot automatically be considered a manifestation of localization: loss of registration and loss of phase coherence represent different observable events and require different parts of the probabilistic model.
(19.1) Example of a two-source readout model. The formula does not describe any installation; it shows how detector errors change the relationship between quantum visibility and the frequency of detected events.
Fully specified experiment with initial readings
The following example is an artificial computational experiment. Its initial events are derived from a given binomial generator rather than extracted from a laboratory measurement. A real replication of the published interference series is discussed in chapter 12. These two materials solve different problems: replication connects the presentation with external observations, and simulation allows you to test a procedure against a known truth and determine the frequency of its errors.
Selected two compact objects from chapter 17. For each, eight settings are made d/ℓ = 0; 0.6; 1.0; 1.6; 2.3; 3.2; 4.5; 6.0, where ℓ = 100 nm. The setting accounts for 1600 of registered two-output events. Additionally, there are 5000 calibration events in which the readout contrast is checked against a known state with zero accumulation time. The total volume of the training series is equal to 30 600 events. The null setting does not measure the spatial mechanism, but limits the constant background along with the calibration.
The model assumes symmetric binary readout and independent repeats. The probability of the “plus” outcome is at the maximum of the interference phase. The contrast c is multiplied by the coherence loss exponent. The coefficients and describe a given background family; the index g distinguishes objects. The quadratic term is an effective approximation over a chosen range, not a universal law of the medium. The presence of a more complex acceptable background is checked separately.
In the generator c = 0.95, b₀₁ = 0.04 s⁻¹, b₀₂ = 0.06 s⁻¹, b₂₁ = 0.008 s⁻¹ and b₂₂ = 0.012 s⁻¹, if the distance squared is expressed in terms of ℓ². In the main signal series A = 0.12 s⁻¹, = ℓ. Zero series have A = 0; weak signal - A = 0.035 s⁻¹. The time of the first series is 1 s, the second - 0.8 s. The mass ratios are fixed to 1 and 1.4. The geometry in this example is known exactly; its additional uncertainty would require separate input calibrations.
The calculations use a = −ln c and the scaled quadratic factors B₂g = 36. This change in coordinates improves the numerical conditioning without changing the physical model. a, two , two B₂g and A are estimated together. All rates are non-negative. Optimization ranges are preset: 10⁻⁵ ≤ a ≤ 0.3; 0 ≤ ≤ 0.3 s⁻¹; 0 ≤ B₂g ≤ 1.4 s⁻¹; 0 ≤ A ≤ 0.7 s⁻¹. These boundaries are part of the teaching procedure and are maintained in all ensembles.
The length is searched on the finite grid /ℓ = 0.50; 0.65; 0.80; 1.00; 1.25; 1.60; 2.00; 2.50. For each value, all other parameters are re-selected, after which the highest likelihood is selected. The grid is fixed before confirming sets are generated. It is not depicted as a continuous search without restrictions: other optima may exist between nodes, and a more dense search would require a new calibration of the procedure. Such a limited protocol is convenient because the scope of its verification is completely defined.
The original entry consists of N and k for each setting. In independent trials, the order of identical two-outcome events adds no information to the binomial likelihood, so these numbers are sufficient statistics. In the present experiment, time and order would also be preserved to test for drift; By definition, there is no drift in this generator. The archive contains all k sets, generator parameters and a fixed seed 20261113. A separate demo set uses seed 20261214 and was not selected for significance.
In this set, the calibration gave 4863 a plus outcome from 5000. The complete two series are presented in the table. Maximization by initial samples preserves the natural dependence of variance on probability. If you first turn them into visibility and logarithmic rates, and then assign the same error to all points, you get a different procedure. Its calibration cannot be automatically borrowed from true binomial analysis.
(19.2) Conditional probability model of the registered outcome. It does not include particle loss; fixed N means the number of trials already registered. In a separate calibration, = (1 + c)/2.
One pre-fixed synthetic set
d/ℓ | k₁ from 1600 | k₂ from 1600 |
0.0 | 1539 | 1528 |
0.6 | 1518 | 1519 |
1.0 | 1515 | 1493 |
1.6 | 1476 | 1472 |
2.3 | 1456 | 1408 |
3.2 | 1401 | 1340 |
4.5 | 1381 | 1294 |
6.0 | 1293 | 1231 |
Same curve for different mechanisms
Chapter 10 shows that spatial localization of a certain type can be reproduced by random impulses from the medium. Chapter 18 gave a temporal analogue: white external dephasing and additional irreversible rate can add up to one inseparable parameter. This is not a flaw in the numerical algorithm. If the probabilities coincide, the algorithm has no information to select a physical origin.
It is necessary to distinguish between exact and practical degeneration. With exact degeneracy, no increase in the number of repetitions of the same protocol solves the problem. In practice, the models diverge slightly, but there is less error available. Then additional statistics sometimes help. However, systematic calibration uncertainty need not decrease with the number of events. A million repetitions of one incorrectly measured distance does not turn it into the correct distance.
Useful work begins with finding explicit parameter transformations that preserve all predictions. If the increase in fundamental intensity can be completely compensated by a decrease in the unknown white background, the direction of indistinguishability has been found. The next experiment should be chosen so that compensation stops working. This could be a different mass, a different spatial profile, an independent measurement of the environment, or an energetic observation. Its value is determined by the violation of a specific degeneration.
Figure 53. The frame defines the available settings and registration. Accurate operational indistinguishability requires equality of distributions across the entire allowed protocol family; in a process with memory - for full multi-temporal statistics, not just one final channel. With such equality, an increase in the number of events does not create missing information. Additional observation or independent access to the environment is only useful when specific models predict different distributions for them. The blocks “Model 1” and “Model 2” indicate explanations rather than individually observed mechanisms.
Local and global distinguishability
Let the vector of parameters be denoted by , and the calculated average observations by . Derivatives of predictions with respect to parameters form the sensitivity matrix . If its columns are linearly independent, small changes in different parameters affect the data in different ways. Under ordinary smoothness conditions, the full column rank serves as a sufficient regular criterion for local identifiability. It shows that in a sufficiently small neighborhood there is no continuous direction of compensation.
A local result does not exclude another solution far from the found one. A nonlinear model may have several separate parameter regions with the same predictions. Therefore, an analytical search for symmetries, studies of likelihood profiles, and numerical launching from different initial regions are necessary. Even a successful numerical search is not proof of global uniqueness in the entire continuous space. Its scope and resolution must be indicated.
The zero intensity boundary is especially important. If the additional mechanism is turned off, its correlation length may not affect the data at all. It makes no sense to estimate it at such a point with the usual symmetric confidence interval. In addition, the insufficient rank of derivatives does not always prove complete nonlinear non-identifiability: there are special points at which the first derivative vanishes. Therefore, rank testing complements model research, but does not replace it.
(19.3) Sensitivity matrix and information matrix in the Gaussian approximation with a fixed known covariance Σ. For raw counting data, information is calculated from the corresponding likelihood.
Figure 54. Projection of a signal onto the space of a constant and quadratic background with equal weights. Only the part not absorbed by this background remains for differentiation; expanding the environmental model can reduce it.
How to exclude a known background shape
The contrast of chapter 10 can be summarized. Let us imagine the set of estimated rates as the sum of a known family of background dependencies, the signal being tested, and the error. The columns of the matrix define valid background shapes, such as constant and squared separation. The vector describes the shape of a single signal at a fixed correlation scale. It is required to construct weights , for which . Then the corresponding combination of data does not depend on the coefficients of the selected background.
With a known positive definite covariance , the problem has an explicit solution: the part that lies in the space of background dependencies is subtracted from the signal. The remainder is then weighted by the inverse covariance. Below is this design for linearly independent columns . For dependent columns, the independent basis is first selected or a well-defined generalized inversion is used. Direct inversion of an almost singular matrix can create artificially enormous sensitivity.
Only the recorded background is reduced. If in reality there is an additional spatial dependence, it may remain in contrast entirely. Therefore, two calculations are useful: a basic one with a physically based model and a stability check with an extended family of permissible deviations. If, after reasonable expansion, the signal disappears, the result should be considered dependent on background assumptions. The very fact of using linear algebra does not make the diagnosis independent of the model.
(19.4) Project the signal outside the selected background subspace in the error metric. Weights should be determined by model and calibration prior to testing on a confirmation sample.
Maximum contrast does not equal the best experiment
In an ideal calculation, one can find the distance at which the absolute contrast is maximum. Actual sensitivity also depends on the number of events, losses, registration errors, and the cost of each run. With greater separation, visibility may become too low and rate uncertainty too great. Then the point with the largest theoretical signal will be less useful than the point with less effect but a more reliable reading.
In the Gaussian linear approximation for a known signal, the following ratio of the expected effect to the statistical error is obtained. It refers to fixed shape parameters and known covariance. If the scale of correlation is searched among many options, the search itself must be taken into account. If a covariance is imprecisely estimated, its uncertainty is also carried over into the result. For real design, it is preferable to calculate the expected initiating events and evaluate the complete analysis procedure on artificial samples.
Bayesian design of interferometric collapse tests considering pressure, thermal radiation and number of measurements was studied by Laing and Bateman [19]. This is an existing example of how experimental geometry is linked to parameter information. In this program, the selection criterion should be supplemented with robustness to an uncertain background: a good experiment should remain distinguishable over a permissible change in calibration, and not just at one most convenient point in the model.
(19.5) The expected signal to noise ratio in the specified linear Gaussian approximation. This is a design tool, not a ready-made detection value in real data.
The minimum set is not specified by one number
The number of measurements and the number of independent observations are two different things. A thousand repetitions with one setting refines one probability. Several different settings can produce a new dependency structure, but only if their predictions are not copies of each other. Therefore, the rule “four parameters, four points are enough” is unreliable. It does not take into account unknown calibration, degeneracy, and the need to check the quality of the model itself.
For a space-time program, a reasonable minimum set is determined by the problem. What is needed are observations that constrain the environment, at least slightly different geometries, a memory-sensitive time sequence, and an independent series to test the transfer. However, these categories do not guarantee success on their own. Before the experiment, a coupled model should be built and it should be determined which parameters remain uncertain. Sometimes one well-chosen additional mode is more useful than a dozen similar options of the previous one.
It is also necessary to measure the input parameters. An error in mass, distance, or duration changes the theoretical prediction itself. Such quantities cannot always be considered absolutely known and all uncertainty cannot be placed only on the vertical axis of the graph. The coupled model can include calibration parameters with individual data. Then the real cost of the inference is visible: what accuracy of geometry and environment is enough for the difference of interest not to disappear.
Testing on held-out data
Once a model is selected, testing is required on data not used to adjust its shape. A delayed series can change mass, distance, temperature, or control sequence. Conditions are chosen in advance so that competing models produce different predictions. A simple random division of almost identical repetitions into two parts tests the reproducibility of the estimate, but is usually a weaker test of the transfer of a physical law to a new regime.
Before opening a confirmatory series, all the rules are fixed: the range of parameters, calibration corrections, the criterion of disagreement and acceptable options for the medium model. This does not prohibit subsequent exploration of the unexpected. It only separates the prediction made in advance from the explanation found after viewing the result. If a new feature requires a model change, the next independent series must check the already changed version.
Different statistical approaches answer different questions. The frequency procedure evaluates the behavior of the rule when repeating experiments; Bayesian updates the distribution of parameters given initial assumptions. The strong dependence of the output on the chosen a priori range should be shown. Neither a high model comparison coefficient nor a low probability in one null model automatically means that all physical alternatives have been taken into account.
A parameter profile and results from the held-out run
For the given readings, the comparison statistics with A = 0 is 57.369. A full length search is included in both this number and the zero calibration of chapter 21. The best estimate of A is 0.15334 s⁻¹. However, the maximum point does not show the width of the uncertainty. If an increase in A is accompanied by a change in and background coefficients, the predictions may change little. This can be seen in the profile likelihood, where for each fixed A the background and the entire length grid are re-optimized.
For the demo set, the profile area along A extends from 0.090 to 0.275 s⁻¹ on the grid step 0.005 s⁻¹. The threshold of the profile difference is equal to 4.2681 and was obtained by separate modeling at A = 0.12 s⁻¹ and the specified background. This is a point calibration in a given internal mode. It does not prove uniform 95 percentage coverage for all possible A, backgrounds and continuous . An actual test of coverage on an independent ensemble is given in chapter 21.
The deferred protocol uses d/ℓ = 0.85; 1.35; 2.05; 2.85; 4.80 and durations reduced by 0.65 times. For each object, there are 800 events to configure; Additionally, an independent registration calibration is maintained. All predictions are calculated using the parameters of the training series. New readings are not involved in re-adjusting A, or the background. This tests the transfer over distance and time, not just the stability of the random division of repetitions of the previous setting.
The total discrepancy between the delayed samples and the forecast in Pearson form is 13.484. Its reference distribution is built by simulating the full path: a new training set, a new selection, and new delayed events. Therefore, the error of the predicted parameters is not considered zero. The tail fraction is equal to 0.392 for 1000 repetitions in the nominal model. In this example, the forecast is consistent with the new series. This is a spot check of the selected generator; extending the background class can change the output.
At the beginning of the second series, the measured probability for the first object is 762/800 = 0.9525; the forecast is approximately 0.95675. For the last setting of the second object, 672/800 = 0.8400 is observed with a forecast of about 0.85109. The difference between individual points is natural for the final counting data. The point of the general criterion is to evaluate the entire sequence according to a predetermined rule, without retroactively selecting the most successful or most divergent point.
If disagreement arose, the next step would depend on its structure. The overall calibration shift is different from the time scale error; Selective divergence of large distances indicates a different part of the model. After verification, the deferred data can be used to develop the next version of the description, but then another independent series will be required. A reproducible procedure makes this transition explicit and allows one to separate the explanation of what has already been seen from a truly new prediction.
Figure 55. Amplitude profile and prediction of delayed binomial events. On the left is the log-likelihood difference after a full grid search ; on the right is the forecast and independent readings of new settings. The vertical dotted line marks the entered A, the horizontal dotted line marks the calibrated threshold. The bars on the right show one binomial standard error of the frequencies, without the error of the predicted parameters; the general criterion takes it into account by separate modeling. All events are synthetic.
The limits of physical inference
After a complete analysis, the result should be formulated at the level that the observations support. It is possible to limit parameters, detect a discrepancy with known background, favor one parameterization over another, or successfully predict a new series. These statements vary in strength. They cannot be quietly replaced by a general statement about the new nature of reality.
The limit of discernibility is also a positive scientific result. If it is proven that the chosen class of measurements does not distinguish between the two hypotheses, there is no reason to repeatedly repeat a useless comparison. You can specify which assumption needs to be added and which observation can test that assumption. This turns the mathematical constraint into a guide for the next experiment.
The results of the analysis performed should be read as a map of conditions: in one area the parameters are definable, in another only their total contribution is distinguishable, in the third everything is hidden by calibration. Such a map is more honest than one maximum sensitivity figure and is more useful for choosing equipment. It explains which uncertainty needs to be reduced first in order for the next measurement to actually add knowledge.


