11 What heating and correlations add
An additional observable is useful when it requires the explanation to make a new consistent prediction. Heating, rotating, and moving multiple probes together really enhances testing. But the number of graphs is not equal to the number of independent evidence. If two mechanisms already define the same total available dynamics, another consequence of this dynamics will not separate them. Therefore, we first need to understand what new physical information each measurement brings, and then evaluate its accuracy.
One reason and two manifestations
The simplest example relates spatial decoherence to momentum diffusion. An impact that randomly changes the impulse can simultaneously blur the relative phase of spatial alternatives and increase the average square of the impulse. In a one-dimensional model, both effects are expressed through a single coefficient . This relationship is especially convenient for testing: fitting the interference loss already determines the amount of additional heating expected. To freely choose two coefficients instead of one would be to test a different, less stringent model.
Let the additional term of the equation have the form of a double commutator with a coordinate. In coordinate representation, it multiplies the density matrix by the square of the position difference. Therefore, the decay rate for separation d is d²/ℏ². To obtain the change in second moment of momentum, the same generator is applied to the operator . The canonical commutator gives double the diffusion coefficient. Dividing by twice the mass converts the result to the rate of growth of kinetic energy along the chosen axis.
This conclusion is a direct consequence of the written equation, and not a separate experimental law. It is useful precisely as a conditional equality: if losses and heating are explained by one such term, their quantities are related. Inconsistency indicates an incomplete model or an error in identifying additional contributions. Consistency indicates that the test is passed, but does not establish the unique nature of the impact.
(11.1) One-dimensional Markov momentum diffusion is assumed. Γ refers to the contribution of the specified diffusion term; other coherence losses are taken into account separately.
(11.2) = /(2m) is the kinetic energy of one coordinate, not the total three-dimensional energy. The additional contributions of one mechanism are compared. The influence of the Hamiltonian, cooling and other sources must be taken into account separately.
When the coupling is no longer simple
The quadratic dependence cannot be transferred to any distance. For the saturated model from the previous chapter, the diffusion approximation corresponds to a small separation relative to . At larger distances, the loss of coherence saturates, while heating characterizes the other side of the same oscillator. Applying a small-scale equality far beyond its derivation creates an imaginary contradiction. Therefore, before comparing two observables, it is necessary to check that both are calculated in compatible approximations.
Another subtlety appears in the installation with cooling. The observed energy may remain constant, although additional diffusion is present: its contribution is compensated by energy removal. The stationary dispersion or overall balance is then tested rather than the non-zero slope of temperature over time. If the model includes dissipation, the formula for pure heating also changes. The conclusion “the temperature does not rise, therefore there is no collapse” without an appropriate balance is not physically determined.
For colored noise, different measurements are sensitive to different parts of the spectrum. Long-term free movement, mechanical resonance and high-frequency radiation use different filters. They cannot be reduced to a single intensity number without specifying the spectral model. [24] However, it is precisely this distinction that can be useful: multiple bands limit the ability to adjust the spectrum. A strong program tests a single family of spectra across all data, rather than assigning each instrument the independent intensity of one supposedly universal process.
Heating beyond the quadratic approximation
For Gaussian shocks from the tenth chapter, the energy growth can be derived without decomposing the spatial kernel. Each push replaces the impulse pₓ with pₓ+q. With a symmetric distribution of q, the average cross term 2pₓq disappears, and the square of the momentum on average increases by the dispersion of the shock. The Poisson frequency A translates the increment of one event into a rate.
With a dispersion q equal to ℏ²/(2), we obtain an increase in one-dimensional kinetic energy Aℏ²/(4m). This result is compatible with the exact saturable rate Γ(d) = A[1−exp(−d²/(4))] for any d in the compact model. In the isotropic three-dimensional version, the same contributions of the three coordinates give a three times greater increase in the total kinetic energy.
Therefore, it is useful to compare not only individual numbers, but also the ratio that eliminates A. The quantity md²Ėₓ/(ℏ²Γ) is equal to u/(1−exp(−u)), where u = d²/(4). For small d, it tends to unity—the diffusion equality of the beginning of the chapter returns. At d = 2 it is approximately equal to 1.582. The discrepancy with unity in this mode does not refute the saturated model: it shows the limit of the quadratic approximation.
Let us now set up a fully numerical simultaneous example. Let us choose the reference length L and the parameters A = 0.5 s⁻¹, = L. The two average rates at d = L and d = 2L are equal to 0.1105996 and 0.3160603 s⁻¹, respectively. It is convenient to express the energy observable as H = 4mL²Ėₓ/ℏ²; its value is 0.5 s⁻¹. All three numbers are accurate model expectations, not random experimental readings.
For comparison, we set the training standard errors 0.005, 0.005 and 0.02 s⁻¹ and assume their independence. Pure quadratic diffusion has one coefficient B: it predicts Γ(d) = Bd²/(4L²) and H = B. Minimizing the sum of squared normalized deviations over the three observables gives B = 0.3332979 s⁻¹. The predictions of such a model cannot simultaneously approach both spatial values and energy growth at the chosen weights.
The minimum weighted discrepancy is 111.12. This is a diagnostic number calculated on mathematical expectations for assigned errors. It is not the p-value of the actual discovery and does not justify the achievability of these installation errors. Its purpose is to show the specific gain of a joint prediction. The full procedure on random initial events and its statistical calibration are discussed in the last part of the book.
The outcome depends on the class of alternatives. This set of observations separates the saturable kernel from the specified pure quadratic model. But Gaussian Poisson shocks with the same A and reproduce all three expectations exactly. Heating strengthened the functional form test while maintaining the original ambiguity of the physical origin.
(11.3) Precise energy growth of a compact Gaussian pulse generator and its relation to spatial loss of coherence. Ėₓ refers to one coordinate.
(11.4) Joint weighted fitting of a single quadratic diffusion parameter. The given σᵢ serve as training scales and not as measured characteristics of the device.
Observable | Saturable kernel | Best quadratic model | Training error |
Γ(L), s⁻¹ | 0.110600 | 0.083324 | 0.005 |
Γ(2L), s⁻¹ | 0.316060 | 0.333298 | 0.005 |
H, s⁻¹ | 0.500000 | 0.333298 | 0.020 |
Figure 27. A joint comparison of two spatial rates and heating. Quadratic diffusion with one selected coefficient does not reproduce all given averages of the saturated kernel under training errors. Precise Gaussian shocks reproduce them completely.
Why rotation is of particular interest
Translational motion reacts to the total force, rotational - to the moment of force relative to the selected axis. These are different ways to weigh the spatial distribution of exposure. If noise is associated with mass structure, a body of complex shape may produce different ratios of translational and rotational fluctuations. Equal total mass does not mean equality of such relations. Therefore, orientation and internal geometry are able to add information that is not present in a single center-of-mass measurement.
Figure 28. Translational and rotational reading of one asymmetric body. In the first case, the change in the coordinates of the center of mass is measured, in the second, the change in orientation relative to the selected axis. The total force and moment of forces provide different information about the spatial structure of the impact. The sensors and camera are shown conceptually; The figure is not a diagram of a specific implemented device.
In 2025, Altamura, Vinante, and Carlesso used LISA Pathfinder rotational noise data to refine constraints on the CSL. The work shows that an already recorded movement can contain additional verification information if you select another observable and correctly recalculate its connection with the model. [20] This does not imply universal superiority of rotational measurements: comparison depends on shape, axis, frequency range and background.
For our own calculation, a natural task is to find a response ratio that is robust to some general uncertainties. But here, too, the reduction of parameters requires verification. If the translational and rotational modes have different temperatures, losses, or calibration errors, the formally simple coefficient may not be reliable. First, a joint mechanical model is derived, then the useful combination is calculated. The reverse order can hide significant differences under a beautiful dimensionless quantity.
Two probes and common noise
If the stimulus has a spatial correlation length, two adjacent probes can move in concert. With greater distance, consistency may weaken. Bedingham and Ulbricht in 2015 considered correlated diffusion of two particles in CSL and proposed using it to test the spatial scale of the model. This is an existing direction, not a new idea for this program. [27] The practical value lies in the transition from the noise amplitude to its dependence on the relative position.
Coincident fluctuations in themselves do not constitute entanglement. General vibration of the base, electric field or unstable laser also create correlations. Therefore, it is necessary to measure the dependences on distance, orientation, charge and connection with a common support. Sometimes a differential channel suppresses a homogeneous disturbance; sometimes part of the desired signal is suppressed along with it. The word "common" does not indicate which of these cases is implemented. The answer is provided by a spatial impact model.
The two sensors can also be correlated via the measuring system. If a common amplifier or computational processing transfers the error of one channel to another, a connection of recordings without a corresponding connection of physical movements is found. Independent readout and control channels are useful, but their independence must also be verified. The requirement here is simple: an observed correlation acquires physical significance only after the path along which it could have arisen has been established.
It is convenient to compare the movement of the sum and difference of coordinates of identical probes. With equal mechanical responses, the common in-phase impulse strengthens the sum channel, and in the difference channel it is reduced. Independent shocks give a different ratio of dispersions. This simple reasoning shows where additional information comes from. But for unequal responses, it is initially necessary to bring the channels to a common physical scale. Otherwise, an imperfect reduction in the overall technical noise can be mistakenly taken for the intrinsic fluctuations of the mechanism under study. The instrumental transfer function is part of the correlation test.
Figure 29. Two probes with independent reading provide sum and difference channels (x₁±x₂)/√2. The total contribution reduces into differences only when the mechanical responses and gains are consistent. Local noise and the overall recording path require separate calibration. Correlation of records does not in itself mean entanglement.
The number that the second probe adds
Let's consider two identical probes in one-dimensional training mode. Their momentum increments have zero means and a covariance matrix 2Ddt, where the diagonal elements of D are equal to D₀ and the off-diagonal elements are equal to cD₀. Positivity of the covariance requires −1 ≤ c ≤ 1. This example specifies the acceptable classical joint noise; it has not yet been identified with a specific CSL mass kernel.
Let us introduce the normalized total and difference impulses p₊ = (p₁+p₂)/√2 and p₋ = (p₁−p₂)/√2. The growth rates of their variances are equal to 2D₀(1+c) and 2D₀(1−c). When c = 0 the two channels receive the same contribution. At c = 1, the total noise completely disappears from the difference channel. Negative correlation, on the contrary, strengthens the difference channel.
If the growth rate ratio measured within this model is four, we obtain c = 0.6. The D₀ scale cancels out, so the ratio limits a different effect property than the absolute amplitude of a single probe. But the equality of the mechanical transfer functions and the independence of the readout are prerequisites for the calculation here. For example, an undetected gain difference leaks common noise into the difference record.
To physically test the distance dependence, it is necessary to derive c(R) from the selected interaction and probe geometry. In the mass model, it is impossible to arbitrarily replace the force correlation with the Gaussian spatial localization function itself: the transition from potential to force introduces derivatives, and the final shape of the body introduces additional weights. Data from two probes add information only after such a connection between the observed relationship and a physical law.
(11.5) Ratio for two equal responses and isolated added noise. Pulse correlation in itself is not evidence of entanglement.
Joint test and its boundary
Dey, Barker and Datta's preprint 2026 proposed limiting CSL through a change in the differential mode dispersion of two nanoballs under Coulomb coupling. The authors also consider resistance to certain color extensions. This is a theoretical proposal with given parameters and assumptions, and not a report of a detected collapse. [29] To evaluate such schemes, it is necessary to check not only the calculation of sensitivity, but also the compatibility of the proposed modes with existing restrictions.
The strongest test requires that a single set of parameters account for loss of coherence, incremental diffusion, and spatial correlations. If this is not possible, the selected model is rejected or refined. If possible, the number of acceptable explanations is reduced, but may not become equal to one. In particular, an exactly equivalent noise generator will continue to reproduce all of its own consequences. Discrimination then requires new information about the environment, its recording, or connections between systems that the original single-particle test did not capture.
Thus, the goal of expanding experiment is not to accumulate impressive graphs, but to increase the number of independent constraints. Sometimes a new observable adds almost no information. Sometimes a comparatively crude measurement destroys a degeneracy that millions of repetitions of basic experiment have not eliminated. This can only be determined in advance through a joint model and an explicit check of its identifiability. This is the subject of the next chapter.
When further runs of the same experiment cannot help
The exact discriminability limit can be formulated for the entire protocol. Let two models have the same initial reduced state and the same quantum channels between measurements for each allowed control. Let the preparation and reading instruments also coincide. Then the probability of any sequence of records is obtained by the same composition of mappings, and therefore coincides for both models.
The proof does not require assuming identical individual histories. At the first step, the unnormalized states for each possible record are matched. Using the same next channel preserves equality. Repeating this reasoning gives equality of probabilities for any finite history. If the subsequent setting is selected based on the previous results, for each already specified history the selection rule is also the same, and the conclusion is saved.
The condition of identical channels for all allowed controls is essential. The coincidence of one free decay curve does not prove it. For a memory environment, coincidence of simultaneous states is also not enough: interventions can reveal differences in multi-temporal statistics. Therefore, what is considered here is the general Markov reduced law with identically enabled control, and not any pair of models that accidentally gives a similar graph.
In the compact white noise example, the CSL-like oscillator and the matched Gaussian pulse oscillator are the same. If all operations affect only the system being described, a new way to measure another function of its state does not establish the origin of the noise. Additional information must go beyond this equivalence: for example, independently constrain the flow of impulses, observe the available record of the environment, or verify the consistent spatial relationships of multiple systems.
This limit is useful for choosing the next experiment. It allows you to separate two tasks in advance: increasing sensitivity to different distributions and obtaining new physical information, without which the distributions coincide. The first is solved by statistics and management within the protocol. The second requires expanding the object being checked along with its model.
(11.6) Probability of a sequence of outcomes as a composition of channels Φ and instruments ℐ. The coincidence of each element of the composition of the two models ensures the coincidence of the complete protocol.
Heating and correlations make research more rigorous by forcing one hypothesis to account for multiple consequences at once. They do not exempt you from analyzing equivalent models. A useful next experiment is selected based on how much ambiguity it is able to resolve, rather than on the number of sensors added.


