12 From raw counts to a verified result
Testing a theory becomes reproducible when the transition from recorded events to the resulting constraint can be traced. This chapter first refines the statistical model and then re-calculates it using the published sodium experiment. It shows which numbers actually follow from the archive, what assumptions are included in the processing, and what remains outside the resulting output.
From an appealing effect to distinguishability
Let us present two explanations for the slight decrease in contrast. In the first, the additional loss depends mainly on the mass. In the second, it is associated with heating, which in the existing installation also increases when working with more massive particles. Given the existing data, both models may look equally convincing. A simple continuation of the series by mass can preserve ambiguity. It may be more useful to measure at the same mass and different thermal histories if the setup allows these conditions to be varied independently.
This reasoning expresses the idea of identifiability. A parameter is identifiable when its different values cannot be fully compensated for by changing other valid parameters, preserving all observed predictions. If compensation is possible, the algorithm may return a narrow uncertainty estimate only due to hidden limitations, such as the background being too rigidly fixed. Therefore, before a large data set, it is necessary to find out which combinations of parameters are generally distinguishable by the selected protocol.
Local verification uses derived predictions across parameters. If a change in one parameter shifts all the expected data almost as much as a change in another, the directions in the prediction space are almost identical. This is a warning about degeneration. However, local analysis does not guarantee global discriminability: distant parameter areas can also produce similar data. It is useful to combine derivatives with direct search for alternative good solutions.
What should a computational model contain?
The simulation input is not only fundamental parameters. We need trajectories, mass and velocity distributions, environmental characteristics, preparation errors, and a readout model. It is advisable to output the original data type: numbers of events, positions of hits, or time series. Modeling ready-made visibility is sometimes convenient, but can hide bias in its estimation. If an experiment first collects samples and then extracts contrast, the test must reproduce both steps.
Formally, what is required is the probability of the data given the parameters and setting. The law under study is denoted by the parameters θ, background and calibration - η, control - u. This notation reminds us that the inference about θ depends on the uncertainty of η. Their joint fitting, profiling or Bayesian averaging are different statistical procedures. None of them eliminate the need to check the physical meaning of acceptable values. The algorithm does not learn on its own that the temperature cannot change arbitrarily between adjacent runs.
In 2024, Laing and Bateman developed a Bayesian formulation for near-field interference tests of collapse models, incorporating external decoherence and choice of control parameters. [19] This is an important existing landmark: the idea of optimizing the experiment through statistical inference is no longer novel. The possible contribution of the new program should be a specific extension, such as robustness to environmental model error, sharing of independent observables, or a new practically achievable regime.
(12.1) This is the probability of possible data 𝒟 given the parameters of the dynamics under study θ, the environmental and recording parameters η and the selected control u. The usefulness of the following experiment is determined by how different such distributions are for competing explanations.
False discovery test
Before the actual experiment, the analysis should be tested on data in which the new dynamics are obviously absent. In this case, the data generator should be slightly richer than the model used in processing. You can add slow drift, weak nonlinearity in the background dependence, or an imprecisely known size distribution. If a small plausible deviation systematically creates the impression of a detected collapse, the method needs to be improved. Testing on your own ideal data confirms only internal consistency, but not resistance to reality.
Effects of known magnitude are then added to the artificial data. It is important to check whether the parameter recovers, how often the intervals contain the true value, and where the sensitivity disappears. Such additions do not constitute experimental confirmation of the hypothesis. They show the capabilities of the procedure under given assumptions. The results should be described as a prediction and accompanied by a list of factors not included in the simulation.
The zero intensity boundary requires special attention. If the parameter is by definition non-negative, conventional approximations for symmetric errors may perform poorly near zero. Additionally, choosing the most salient distance, frequency, or time window after reviewing the data increases the likelihood of randomly striking variation. Therefore, the search range and decision rule are either specified in advance or included in the modeling of the statistics of the entire procedure. Otherwise, the significance of a single point does not describe the significance of the study.
The results of such computational tests should be kept separate from experimental observations. Each artificial sample has a known generation law, which means it allows you to check a specific analysis failure. It does not confirm that nature chose this law. A useful report therefore contains both successful recovery and failure modes. For example, if the range of distances is too narrow, the two models may be virtually indistinguishable even in a perfect simulation. Showing this area upfront is more helpful than hiding it behind one favorable example with a lot of contrast.
Cost and information
Practical optimization must take into account the cost of measurement. One mode gives a large signal, but requires a long readjustment and has a low rate of successful launches. The other is weaker in each individual event, but allows you to quickly collect independent data and carry out calibrations more often. Comparing amplitudes only misses this exchange. You need a goal expressed in terms of information or precision with limited time, number of particles and available control set.
For a consistent result, it is useful to evaluate not only the most favorable background parameters, but also a reasonable range of uncertainty. A tuning that is excellent when the temperature is only known with certainty may be poor when the temperature drifts slightly. A more moderate protocol sometimes maintains discriminability throughout the acceptable range. Thus, the challenge of sustainable design arises: to select an experiment that remains meaningful despite the foreseen errors of knowledge.
There are also physical limitations. You cannot optimize each setting independently if they are linked in a real installation. Mass affects preparation, geometry affects mechanical response, and retention time affects the likelihood of survival. The admissible set of controls must describe these connections. Otherwise, the program will find a mathematical maximum in the region where the object cannot be prepared or counted. The feasibility check is included in the calculation itself, and is not added to the beautiful result later.
The archive as a definition of a repeatable experiment
The basis is the open set of Pedalino and co-authors with DOI 10.5281/zenodo.17502163, associated with the Nature article 649, 866–870. Its measuring part contains scans from April 22 2025, a table of powers and reference signals, as well as mass spectra. The archive contains programs for extracting visibility, calculating macroscopicity, and the Talbot-Lau module. Materials are distributed under CC BY license 4.0. [15, 63]
To repeat, the archive itself is first recorded. The checksum MD5 of the original ZIP is equal to 7917961b27676f4e9df3af6d3b01c374; it matches the repository entry. This identifier distinguishes specific bytes from subsequent page updates. Next, the source files are saved without changes, and execution is carried out in a separate working copy. Library versions and exact commands are given in the accompanying instructions for the calculations.
Next, elementary checks of the structure are performed: the table specifies 95 names, each corresponds to a file with a 41 position, the counters are non-negative, the displacement units are converted from nanometers to meters. The real powers of the three grids for each launch are taken from the table. Using average power alone instead of these lines would change the probability of passing and would no longer be a repeat of the issued procedure.
The entire set contains 3895 numerical points and 10 772 714 counts. These are two different volumes: one point represents the accumulation of many events at a given position. The integration in all selected lines is equal to one second, so the count and numerical frequency coincide only due to the specific accumulation time. For another table, this equality would have to be replaced by explicit multiplication by time.
Internal control files allow the processing to be repeated independently of the literature description, but do not turn all calibrations into precise physical facts. For example, the reference flux is measured separately and is used in the published likelihood as a fixed number. A more complete analysis could include the uncertainty of this measurement. Reproducing the original procedure preserves its conditions and specifies them exactly.
Figure 30. There are two ways to verify the published sodium set: rerunning the author's open procedure and independent verification of individual calculations. The archive contains 95 scans at 41 position, that is, 3895 measurement points, and 10 772 714 registered events. The independent branch includes the selected scan 54 and the integration test; the length in the issued procedure is fixed to 10 nm. This is a replication of the analysis under its calibration assumptions, not a new experiment or a complete re-evaluation of the calibrations.
One scan and independent visibility extraction
To see data before complex output, scan Sodium_int_powerscan_54 is selected. The selection rule is specified through the setting: this is the line with the power of the second array closest to 15.2 mW. Maximum contrast search was not used. The actual power is 15.252 mW. In 41 position the 132 283 count is registered.
With a known period, the signal can be written as the sum of a constant term, cosine and sine. This notation is linear in three coefficients, so the minimum of the sum of squares can be found using ordinary linear algebra. The coefficients are then translated into visibility and phase. This is an independent path to the same sinusoidal description, which is convenient to compare with the nonlinear fit.
For the selected scan, the average count level 3217.865 per position, visibility 0.07320 and its residual standard error 0.00814 were obtained. The phase is −2.58149 rad at the accepted origin. The figure shows actual readings and its own fit; the vertical segments √n give only a visual Poisson scale. The visibility error estimate is calculated from the residual covariance matrix of the linear regression.
This result refers to one pre-selected row, not the maximum visibility across the entire article. The variation between runs, drift and power changes do not disappear after a beautiful fit of one sine wave. All data provided and the full response of each setting are important in the final analysis.
For a small number of events, the amplitude recovered as the positive modulus of the two noise coefficients has a biased distribution. A simple symmetrical error is then insufficient. Here, high scores allow the linear fit to be used as a transparent description of the selected scan; The fundamental constraint below is reproduced based on the original counters, not just the extracted visibility.
(12.2) Linear fit determines a, b, c. The transition to visibility is nonlinear, so its error is obtained by transferring the full covariance of these coefficients.
(12.3) The phase is determined relative to the beginning of the grating displacement. The dispersion formula is a local approximation; near zero amplitude the full distribution should be used.
Figure 31. Published scan samples 54 and independent linear sinusoidal fit. The choice was made based on the proximity of the power to 15.2 mW. Received V = 0.07320 ± 0.00814; the error is described in the text. Data from Pedalino et al, CC BY 4.0; processing and drawing were done for this book. [63]
How the probability of registration depends on the modification
The original procedure considers a family of minimal macrorealistic modifications. Its classicalization time τe is normalized to the electron mass; the length ℏ/σq determines the spatial scale. These designations cannot be directly equated to the intensity and length of another CSL convention. To transfer, it is necessary to compare the generators themselves and the normalization of masses. [65, 66]
First, the quantum probability of the passage of three gratings is calculated, taking into account their amplitude and phase action. The non-zero harmonic is then multiplied by a modification factor depending on the trajectory and mass form factor. Averaging is done over velocities and masses, as in the released module talbotlau.py. In the chosen procedure, the spatial scale is fixed at ℏ/σq = 10 nm, the published setting used for the final assessment.
For a point with a recorded number c and a separately measured reference signal C₀, the author's analysis uses a conditional likelihood of binomial form on the probability of passing S. The reference signals are 17.5–26.5 thousand samples per second and are conventionally fixed as the number of trials; their measurement uncertainty is not common in this replication. The term that does not depend on τe does not affect the shape of the posterior distribution and can be omitted. The key operation is to sequentially add the logarithms of the probabilities of all points. At the same time, the phase −2.48 rad and calibration dependencies from the archive are recorded.
The posterior distribution is obtained by multiplying the likelihood by the Jeffreys prior density of the selected model. Time τe is considered on a logarithmic grid of 400 points from 10¹⁴ to 10¹⁶ seconds. Logarithmic grid - a method of placing nodes; it does not by itself specify a uniform density in log τe. When normalizing, the intervals of exactly the variable with respect to which the density is determined are used.
The lower fifth percentile τ₅ means that 5% of the probability in the adopted posterior density lies below it. It is used to construct the measure of macroscopicity. This is Bayesian inference within the stated model and calibration. It is not a universal frequentist probability that quantum mechanics is wrong, and it does not establish the existence of an additional collapse mechanism.
(12.4) The probability Sᵢ includes control, averaging over distributions, and selected modification. The C₀ᵢ reference numbers in this replication are treated the same as in the released analysis.
(12.5) πⱼ is the selected Jeffreys density. The lower quantile is calculated from the normalized density, and not from its maximum value.
The reproduced published estimate
Unmodified Macroscopicity_April2025.py and talbotlau.py were executed on the original data. The calculation gave τ₅ = 2.842065516 × 10¹⁵ s and μ = log₁₀(τ₅/1 s) = 15.453634. In the Methods section of the article, 2.84 × 10¹⁵ s and μ = 15.45 are indicated; in the annotation the number is rounded to 15.5. The coincidence is within the rounding limits given by the authors. [15, 63]
Additionally, the Kullback–Leibler divergence between the final density and the corresponding Gaussian approximation is reproduced: 0.001267708. The article shows 1.27 × 10⁻³. Here this value characterizes the shape of the resulting distribution; it does not replace the probability of false discovery of new physics.
To separate the physical result from the way the quantile was read, the density was independently normalized by trapezoidal integration and the position of 5% interpolated between adjacent nodes. We obtained τ₅ = 2.827503744 × 10¹⁵ s and μ = 15.451403. The difference in μ is approximately 0.00223 and is less than the accuracy with which the result is given in Methods. This is a test of the numerical quantile extraction on the same grid, rather than an independent physical calibration.
The measure μ is the logarithm of the limited time in a certain class of modifications. It is not equal to the number of worlds, the degree of consciousness of an object, or the universal percentage of its quantumness. Its meaning is determined by the selected family of dynamics, mass normalization, and statistical limitation procedure. Comparisons of μ between trials are meaningful when this construct is used consistently. [65, 66]
The result shows that the published numerical procedure can indeed be reconstructed from the open set. At the same time, repetition of the source code and independent construction of the physical description solve different problems. The first checks data availability, calculation compatibility, and the published number. The second must vary calibrations, alternative backgrounds, and the probability model itself. For the last problem, a separate controlled numerical experiment is constructed in subsequent chapters.
Magnitude | Publication | Recalculation |
Number of points | 3895 | 3895 |
Lower 5%-quantile τ₅ | 2.84 × 10¹⁵ s | 2.842065516 × 10¹⁵ s |
μ in the Methods section | 15.45 | 15.453634 |
KL to Gaussian density | 1,27 × 10⁻³ | 1,267708 × 10⁻³ |
μ with CDF interpolation | Not a separate published result | 15.451403 - sampling check |
Figure 32. The result of repeated execution of the open author's procedure: a posteriori time density of classicalization and its lower five percent quantile. Densities are normalized to their own maxima only for the figure. Data and initial procedure [63], own design.
What exactly is verified by repetition
The comparison performed saves the settings of the released procedure. It confirms the calculation at a fixed length 10 nm, a given mass window, phase and photophysical dependencies. Finding a maximum over all spatial lengths and re-evaluating all calibrations together would be different analyzes with a different parameter space. Their result cannot be attributed to the repetition described simply because the original article discusses a broader program.
The seventh and ninth chapters show why this limitation matters. The gas composition, grating vibrations, and treatment of the dark background can change the estimated residual loss. A result obtained with one calibration does not demonstrate insensitivity to those parameters. Testing that requires additional data or an explicitly bounded sensitivity analysis. General measurement theory requires a claim to include the conditions actually used.
In the computational application, the original measurements are separated from the artificial series. Real files retain names, checksums, and attributions; artificial series preserve the initial number of the generator and the generation law. This separation allows both the published experiment and the statistical method to be tested without turning a successful simulation into a fictitious observation of nature.
After replication, the choice of next step becomes concrete. You can change one calibration relationship and measure the shift in the result; source and transmission can be jointly assessed; you can compare two designs at the same time. In chapters 19–21, tests of full search, restoration of the introduced signal, interval coverage and prediction of new conditions are performed on a model for which the true parameters are known. Here this model receives real experimental support and a clear transfer limit.
The open sodium archive gives a reproducible external result: μ = 15.453634 in the released procedure, consistent with the published rounding. The usefulness of this check is the traceable relationship between the files, the probabilities and the number. The next level of research requires similar transparency across uncertain calibrations and competing backgrounds; The last part of the book is devoted to it.
Part III Gravity and physical clocks