18 Memory and controlled decoherence hypothesis
The disappearance of interference can be studied not only by changing mass and distance. There is one more lever: to change the order of interactions in time. If the environment retains its properties for some time, correctly chosen control can partially cancel the accumulated random phase. This capability allows the measurement of noise memory but requires caution in drawing conclusions about the origin of irreversibility.
Memory as a measurable property
The timing hypothesis states that a selected component of phase fluctuations has a reproducible correlation scale and predicts the results of different control sequences. Here it is tested as an independent sensor model. The transfer of parameters to mass spatial localization is not expected: it would require an additional interaction law, discussed at the end of the previous chapter.
The very idea of applying dynamic decoupling to testing alternative quantum theories had already been proposed by Arenz, Hiller, Fraas and Burgart in 2015 [47]. Therefore, the use of impulses is not an application for the discovery of a new method. The subject of our own program is already here: which damping components are actually distinguishable with finite control accuracy and with a preliminarily limited, but fairly wide class of surrounding influences?
There are also non-Markov models of spatial localization. Bassi and Ferialdi investigated such dynamics, including exponential noise correlation, in 2009 year [55]. The following calculation is simpler than these models: it is an exactly solvable problem of random phase action on a two-level system. It is needed to check the measurement logic. It cannot automatically be declared to be a complete stochastic collapse equation or a solution to a single outcome problem.
A model with one memory timescale
Let us consider two branches of the state, between which a random relative phase accumulates. In the chosen approximation, the impact is described by the Hamiltonian . The value is measured in reciprocal seconds and has a zero average. A stationary Gaussian process with correlation is assumed. The parameter sets the characteristic amplitude of frequency fluctuations, and sets the time during which the connection between them noticeably weakens.
In this chapter, “memory” means precisely the finite duration of correlations. This usage is not equivalent to any definition of non-Markovian evolution accepted in quantum theory. For example, the absence of return of state distinguishability does not yet make the noise white. For the control problem, the specific correlator and how the system accumulates the phase under its influence are essential. Terminological classification cannot be used instead of calculating observed dynamics.
Let ideal impulses change the sign of the perceived fluctuation; this is described by the function with values plus or minus one. The normalized visibility is . Here is a separate non-negative white phase noise rate, the origin of which has not yet been determined. For the Gaussian phase, the average of the exponential is expressed entirely in terms of its dispersion, which gives the double integral below. Pure dephasing is considered; Energy relaxation should be introduced separately if it is significant.
(18.1) Half the variance of the accumulated random phase. Gaussianity ensures the accuracy of this formula for the selected model; for a general non-Gaussian process it is usually insufficient.
Two ways to accumulate phase
In the Ramsey sequence, the sign of the effect does not change. A slow random frequency shift affects the system all the time and creates a large phase spread between repetitions of the experiment. In Hahn echo, a perfect inversion is performed in the middle of the interval. The almost constant part of the shift in the second half compensates for the contribution of the first. If the fluctuation has changed significantly, compensation becomes incomplete. Therefore, comparison of two sequences contains information about the rate of change in noise.
Substituting these two functions into the integral gives closed expressions. To make them shorter, let's denote them as . Both quantities are dimensionless: the product does not carry units. The formulas can be verified by direct integration and expansion in a short time. This is a useful independent check of the coefficients, since a missing factor of two changes the estimated sensitivity of the entire protocol.
Using control as a frequency filter is a developed area. Alvarez and Suter proposed reconstruction of the color noise spectrum using sequences of inverting pulses [48]. In the workpiece under consideration, this general idea is deliberately reduced to a single correlation time. Simplicity allows one to clearly see both the useful signal and the degeneracy of the parameters. After this check, you can make the spectrum more complex, keeping the known limiting case as a control.
(18.2) Accurate attenuation rates for Ramsey and ideal Hahn echo with exponential correlator. The R and E subscripts denote two control methods, not different noise models.
Figure 49. Ornstein-Uhlenbeck Gaussian noise model with σ τc = 1 without additional white contribution. The echo suppresses the influence of slow fluctuations, but does not prove the fundamental origin of the remnant.
What does the visibility ratio show?
From both sequences it is possible to construct a ratio of normalized visibilities. The common white multiplier disappears, and only the expression through the parameters of the correlated component remains. This doesn't mean there is no white noise. It is simply excluded by the selected combination of observations. This distinction between the absence of an effect and insensitivity to it is fundamental for any diagnostic value.
At times much shorter than , Ramsey's main attenuation is proportional to , and echo's is . Therefore, the inversion changes the initial time dependence. For very long times both curves have the same asymptotic slope: . Their ratio tends to be constant. If you measure only this late section, you can establish the overall slope fairly accurately, but still poorly separate its components.
The practical conclusion is that it is necessary to observe the transition region where the experimental time is comparable to the correlation time. If the scale is initially unknown, a survey series with different times is required. The selected parameters should then predict the outcome of another sequence that was not evaluated. Otherwise, a successful description of the two curves may only reflect excessive flexibility in the fit or features of their overall calibration.
(18.3) Exact exclusion of the total white rate in the idealized model. A consistent normalization of visibility and separately taken into account errors of additional pulses are assumed.
White noise and fundamental ambiguity
Let the correlation act instead of finite memory. Then the double integral turns into . For ideal sign changes, the square is always equal to one. Neither Ramsey nor echo eliminates such contributions. In the limit of the exponential model, white noise is obtained when tends to zero and the product is preserved, and not when the amplitude is fixed.
Therefore, an unremovable decay residue in itself does not indicate a fundamental collapse. It can be provided by a fairly quick external process. If two mechanisms produce the same complete statistics of available controlled measurements, new repetitions of the same experiments will not separate them. Discrimination would require either additional physical constraints on the environment or another observable quantity for which the models actually diverge.
Even the apparent plateau of error as the number of pulses increases needs to be verified. It may occur due to control lane limits, accumulation of turning errors, or other channel loss. Reference to the mathematical limit of infinitely fast ideal operations does not justify the derivation for a finite sequence. It is necessary to calculate what each compared model predicts given the actually available form of the control signal.
The control must influence the desired degree of freedom
For a spin qubit, an inverting pulse changes the orientation of the internal state. In a spatial interferometer, a similar operation may require an exchange of trajectories or specially calculated movement of wave packets. These actions are not automatically equivalent. Rotating the spin without changing the mass distribution does not become a test of mass-proportional localization simply because it improves spin coherence. First you need to establish what physical difference exists between the branches of the state being tested.
Real pulses have a finite duration. During a turn, the carrier may change continuously, so the description in one momentary sign becomes an approximation. In addition, the control field is capable of heating an object, changing its trajectory, or introducing its own fluctuations. For each sequence, the overall response and preparation and readout losses should be calibrated. The general normalization of the two types cannot be declared identical only from the symmetry of the ideal scheme.
Experimental noise spectroscopy on a superconducting qubit was demonstrated by Bylander et al [49]. This result confirms the ability to explore the environment through control, but does not automatically transfer the achieved characteristics to a massive spatially separated state. Separating these concerns is useful: processing methods can first be tested on an available sensor, and the sensitivity to the proposed mass mechanism can be calculated for a different, physically appropriate degree of freedom.
Calculation of a rectangular pulse of finite duration
Let's look at control that actually takes time. In the middle of a sequence of duration T, a rectangular pulse is applied around the x axis. It lasts = fT, and its angular velocity is Ω = π(1 + ε)/. Here f is the fraction of time inside the pulse, ε is the relative error of the angle. Before and after it, the system freely evolves along (T − )/2. This definition preserves the same total Ramsey and echo time: the impulse is included in the budget, rather than added to it unnoticed.
During rotation, phase noise continues to operate. The complete Hamiltonian contains both Ω and [δω(t) + Δ]. These operators do not commute. Therefore, replacing the influence with a single sign y = ±1 inside the pulse is no longer accurate. The calculation extends the entire Bloch vector, including the transverse component and the temporary change in the longitudinal one. General methods for taking into account arbitrary control and the finite shape of pulses were developed, in particular, by Green and co-authors [67].
Figure 50. Ramsey, ideal Hahn echo and rectangular pulse echo are compared at one total time T. In the finite-pulse protocol, the pulse occupies within this interval, and both free sections have a duration of (T−)/2. In the pulse, the transverse control Ω and the phase action [δω(t)+Δ] act simultaneously; a continuous blue line marks the continuation of noise exposure. Their noncommutative dynamics are calculated from the full Hamiltonian, rather than by arbitrarily smoothing the scalar sign of y. The scheme does not assert the suppression of the white component by an ideal echo and does not transfer the result of the spin test to mass localization without a separate communication model.
For a stationary Ornstein–Uhlenbeck process, the calculation can be performed without randomly enumerating trajectories. The Bloch vector, conditional on the noise value, is expanded in terms of orthonormal Hermite polynomials. The OU operator is diagonal along n: each mode decays at a rate of n/. Multiplication by noise relates neighboring modes with coefficients σ√n and σ√(n + 1). At each section of constant control, a finite linear system is obtained; its solution is found by the matrix exponential.
Used σ = 1.2 s⁻¹, = 0.8 s and zero true white rate. The experiment times are 0.12; 0.20; 0.35; 0.60; 1.00; 1.60; 2.40 and 3.20 s. Initial state - +x; registration contrast c = 0.96. The calculation with 36 Hermite modes is compared with 24 modes: the maximum difference in the Bloch components is less than 3·10⁻¹⁵. The instantaneous limit coincided with the analytical formulas of Ramsey and Hahn echo up to 2·10⁻¹⁵. These tests validate the solution of the selected model rather than the description of a specific experimental sensor.
The resulting average probabilities are then deliberately processed by the ideal instant echo formula. σ, and non-negative were selected; the original readout contrast was assumed to be known. Random counting noise was not added at this step: it is necessary to isolate the systematic bias created by the incorrect description of the pulse. The residual after fitting therefore measures the misfit of the models and is not a p-value.
The table shows the gradual appearance of false white rate even at an error-free angle π. At f = 0.01 the displacements are small, but at f = 0.25 the reconstructed is already close to 0.00762 s⁻¹, although its true value is zero. Increasing the number of repetitions will not eliminate this effect: it will only more accurately reveal the difference between the finite pulse and the ideal analysis. The allowed duration depends on the required output accuracy. For a given set of times, for f ≤ 0.03, the error in the predicted probability after a perfect fit is less than 3·10⁻⁵; it is impossible to transfer this numerical limit to another σ, or pulse shape.
(18.4) During a square pulse, Ω is constant; outside the pulse it is zero. For calculations without detuning Δ = 0. In cases with angle error, Δ = 0.15 s⁻¹ is additionally considered only within the pulse.
(18.5) Equations for Hermite modes of the conditional Bloch vector. Lₐ performs a cross product with the unit axis vector a. The observed mean vector is r₀; initially r₀ = (1,0,0), the remaining modes are zero.
Perfect fit to finite pulse data
f = /T | Estimate σ, s⁻¹ | Estimation , s | False , s⁻¹ |
0.00 | 1.20000 | 0.80000 | 0.000000 |
0.01 | 1.19998 | 0.80002 | 0.000012 |
0.03 | 1.19979 | 0.80021 | 0.000111 |
0.10 | 1.19767 | 0.80212 | 0.001242 |
0.25 | 1.18731 | 0.80826 | 0.007619 |
Average synthetic probabilities; ε = 0 and there is no detuning. The value in the first line about 2.4·10⁻⁸ s⁻¹ is the numerical remainder of the optimization at true zero.
Figure 51. Bias of ideal estimates under finite rectangular impulse. True white rate is zero; the growth of the restored is caused by a mismatch of control models. Synthetic calculation of the OU sensor with σ = 1.2 s⁻¹ and = 0.8 s.
How a readout error creates an additional mechanism
The physical action of the impulse and the recording of the result must be modeled separately. In the following control case f = 0.03, angle error ε = 0.03, and during the pulse there is a detuning 0.15 s⁻¹. With a correct overall reading, the ideal fit gives around 0.000151 s⁻¹. Now an additional contrast reduction has been introduced only for echo by 1.5%. It can be represented by a symmetric registration error that occurs after the control sequence. This reduction is physically permissible, but is not present in the erroneously used general calibration.
The ideal model then returns σ ≈ 1.13873 s⁻¹, ≈ 0.88009 s, and ≈ 0.03619 s⁻¹. The correlation time is overestimated by approximately 10%, and the white component appeared entirely from a technical discrepancy. In this example, the residual maximum probability error after fitting reaches 0.00514. With a large enough sample, the model itself can be rejected based on the quality of its description; with a small sample, its flexibility may be sufficient to produce plausible but biased parameters.
The control procedure follows from the model: separately measure the response after each control sequence, save the number of operations and evaluate the dependence of the reading on the mode. Times missing during selection become an additional check. If the finite pulse is included in the propagation, and the difference between and is described by its own calibration, resampling the average data gives σ = 1.19999964 s⁻¹, = 0.80000065 s and the white rate 1.63·10⁻⁷ s⁻¹. These results are consistent with the entered values within the numerical error of this calculation. For random outcomes, you will need to repeat the same test with finite statistics.
The example sets the conditional boundary of the method. The presence of a residue with frequent management does not determine its origin. A useful remainder is one that survives independent calibration, correctly calculated pulse action, and prediction of new regimes. This requirement directly links experimental accuracy with the strength of fundamental inference.
Two sensors expand verification
One sensor reports how noise changes over time at its location. Two sensors additionally make it possible to study joint fluctuations. For clarity, let us assume the same local correlators and cross-correlation , where is the distance between the sensors and . The common and difference phases then experience different attenuation. Their comparison can exclude the independent white component, but only if the independence of this component is explicitly stated.
In the simplest model of coherence between the states 00 and 11, as well as between 01 and 10, they have the following visibilities. Multiqubit spectroscopy of self- and cross-spectra of Gaussian noise has already been developed by Paz-Silva, Norris and Viola [50]. This formula is a special case study that shows the meaning of additional information. It does not cover arbitrary quantum environments or all possible types of interqubit communication.
The working hypothesis of finite memory is rejected in the selected range if a single correlator does not predict the delayed sequences and spatial correlations after accounting for calibration. However, failure of the single-exponential form does not reject all processes with memory. The next comparison would be multi-scale or non-Gaussian noise. For the latter, there are protocols using higher order spectra [51]; simply changing the value of may not be enough.
(18.6) The plus sign corresponds to the common phase of two identical sensors, the minus sign corresponds to the difference. Equal control, Gaussianity, and independent white local noise are assumed for each sensor.
From two coherences to joint counts
To make two views observable, preparation and reading are specified. For the general phase, the state Φ⁺ = (|00⟩ + |11⟩)/√2 is prepared; for difference - Ψ⁺ = (|01⟩ + |10⟩)/√2. It is assumed that the preparation has already been calibrated, there is no direct interaction between the sensors during accumulation, and the influence of control signals has been taken into account. Under these conditions, pure dephasing leaves the populations unchanged and multiplies the corresponding off-diagonal pair by v₊ or v₋.
In each series, X⊗X and Y⊗Y are measured. For Φ⁺ their means are v₊ and −v₊; for Ψ⁺ - v₋ and v₋. Therefore, the combinations [⟨XX⟩ − ⟨YY⟩]/2 and [⟨XX⟩ + ⟨YY⟩]/2 give the two required coherences. These are specific two-channel correlators: for each repetition a pair of signs is stored, and its product takes the values ±1. The random coincidence of individual local averages is not enough here.
When measuring XX, the probabilities of identical signs ++ and −− are equal to (1 + v)/4 each, and of different signs +− and −+ - (1 − v)/4. Therefore, the variance of the estimated correlator from N events is equal to (1 − v²)/N. Two independent measurement bases reduce the variance of the corresponding average combination to (1 − v²)/(2N) if N repetitions are performed in each. The resource distribution between bases must be explicitly indicated: the same particle cannot be considered twice measured in incompatible bases.
Figure 52. The preparation Φ⁺=(|00⟩+|11⟩)/√2 is sensitive to the overall phase, and Ψ⁺=(|01⟩+|10⟩)/√2 - to the difference. Readings XX and YY are performed in different repetitions: for Φ⁺ the means are v₊ and −v₊, for Ψ⁺ - v₋ and v₋. Each entry contains a joint pair of characters; the correlator is assembled from four joint event numbers. In the numerical example of the book, 4000 events are allocated for each of the four series, in total 16 000. Calibrated preparation, accounted management and lack of direct interaction during accumulation are assumed. Difference coherences do not eliminate arbitrary technical noise, and joint correlators cannot be replaced by local means. Volumetric sensors are conceptual images of functional modules.
The numerical example uses the same σ and , time T = 1 s, local white rate = 0.03 s⁻¹ and cross-correlation c(R) = 0.4. It turns out = 0.494443, v₊ = 0.235878 and v₋ = 0.520310. The logarithmic difference restores c(R) = 0.4. For 4000 events for each of the four preparation × basis sets, the linear estimate of the standard error c is about 0.0251 if χ is known exactly. A total of 16 000 events are required.
This budget does not yet include the uncertainty of χ, imperfect preparation, mutual interference, and the difference between the two detectors. Their inclusion will increase the error and may change the optimal distribution of replicates. The value of the example lies in the completed chain from the state to the four probabilities and the correlation estimate. General multiqubit spectroscopy is significantly broader than this symmetrical classical model [50].
(18.7) The last equality uses the same control, the known and the independent equal white component. The logarithm cannot be applied to a negative noise estimate of visibility without a separate statistical model.
The form of control is included in the law of observations along with the noise correlator. The completed example shows both the usefulness of echo and the cost of incorrect calibration. For spatial measurements, the same problem arises: to determine what information is carried by the initial events and what differences in mechanisms remain after the joint assessment of all unknown quantities.



