7 How to find the superposition limit
The question of the boundary of the quantum world becomes physical only after it is specified which system must preserve the superposition, how long it must retain it, and what observation will confirm this preservation. The phrase “a large object behaves quantumly” leaves too many uncertainties. Quantum can be one internal transition, collective excitation or movement of the center of mass. To test the assumed spatial localization, these cases are not equivalent. The beginning of the study therefore looks modest: a specific degree of freedom is selected and it is established what exactly the device can say about it.
What does it mean to place an object in superposition?
Let us imagine a particle whose motion is controlled in such a way that two spatial alternatives can later meet again. As long as alternatives exist, one cannot observe them separately and simultaneously require that all the original interference be preserved. The test works differently: the control changes the relative phase, and the distribution of the final results responds to this change. If detection frequencies change regularly, the observation contains information about the mutual consistency of the alternatives. Simply not knowing which path an ordinary particle has taken does not in itself create such a phase dependence. However, the stripe pattern still needs to be compared with suitable classical models of the device.
This last caveat is especially important for grids and periodic masks. A sequence of holes can create flow inhomogeneity without spatial quantum coherence. Therefore, a convincing experiment tests the dependence of the signal on the control parameters, and not just the existence of a beautiful pattern. In January 2026, the group of Sebastian Pedalino and co-authors reported the interference of sodium nanoparticles containing more than seven thousand atoms and having a mass of more than 170 thousand daltons. The experiment expanded the area of the tested spatial superposition, but did not detect its violation. Testing a specific mass and geometry does not establish a universal limit to the applicability of quantum theory. [15]
Four scales instead of one mass
To plan a study, it is useful to mentally decompose the experiment into four scales: the mass of the object, the distance between the alternatives, the time of their existence, and the spatial structure of the body itself. Mass determines sensitivity only together with other parameters. A heavy particle whose positions differ by an extremely small amount may be a less sensitive probe of a particular pattern than a light particle with a larger separation. Similarly, long-term retention of almost identical branches does not have to replace short-term retention of clearly distinguishable ones. The answer depends on how the proposed mechanism differentiates the distributions of matter.
Body size adds its own difficulty. If the hypothetical noise is consistent across the entire object, the contributions of its various parts can add up together. If the correlation length is small compared to the size, different regions begin to respond differently. Replacing the complex mass structure with a single point then changes the prediction. A practical conclusion can be obtained even before detailed calculations: the table of the prospects of experiments should contain information about density and shape, and not just one column with mass. A ranking based on the number of atoms is convenient for reporting the result, but is not sufficient for choosing the next experiment.
A simple analogy with measuring terrain helps here. It is pointless to evaluate the sensitivity of a ruler without the size of the irregularities that need to be distinguished. In a quantum experiment, the role of this size is played, among other things, by the correlation length of the influence being studied. A probe whose settings never cross the appropriate spatial scale can only see a local approximation to the law. Several different physical dependencies within a narrow range become almost identical. Increasing the number of repetitions reduces statistical error, but does not always eliminate this geometric ambiguity.
Figure 15. Four characteristics of spatial experiment: mass m, duration T, separation of alternatives d and mass structure μ(r). The body radius R is shown separately from the distance between the centers of the alternatives. The two translucent positions refer to one state, not two independent classical particles. Dimensions are relative; the figure does not report new records and does not depict the correlation length as a field boundary.
What does visibility measure?
It is convenient to characterize an approximately sinusoidal interference signal by visibility: the ratio of the difference between the maximum and minimum values to their sum. This value lies between zero and one with a normal positive signal. It answers the question of how pronounced the alternation of light and dark areas or high and low registration frequencies is. On its own, it does not explain the reason for the weakening. Imperfect preparation, velocity spread, phase fluctuation, particle loss, and physical destruction of coherence can change the observed contrast in different ways, sometimes simultaneously. Therefore, a reference visibility is needed for the same control sequence.
In a thought experiment, one can assume that the reference visibility is precisely known and write down the exponential decay at a constant rate. In the actual procedure, the reference visibility is also measured or calculated with error. If the separation of branches changes over time, each part of the trajectory contributes its own share of losses. The maximum distance between branches does not replace the movement history. Two experiments that reach the same maximum separation may accumulate very different losses because one lingered in that state and the other quickly moved through it. This difference should be included in the model before comparison with the data.
(7.1) The first formula determines the visibility of a suitable interference signal. The second describes the additional attenuation for a given separation trajectory d(t), if the time-local rate model Γ is applicable and the reference visibility V₀ is correctly defined. This is a working approximation and not a universal property of all open systems.
How lack of effect becomes a result
Suppose the model predicts an almost complete disappearance of interference, and the instrument consistently observes a noticeable contrast. If the background and preparation are checked, the relevant model parameters can be eliminated. This is a meaningful answer, although no new particle or force has been found. It shows what the mechanism we are looking for cannot be. But the negative result has a conditional form: the parameter range is excluded under certain assumptions about noise, mass distribution and time dynamics. To replace such a formulation with the statement “there is no collapse” means losing most of the knowledge gained.
Another way uses side effects of the proposed mechanism. In March 2026, the XENON collaboration published a search for spontaneous X-ray emission in XENONnT data. No significant signal was detected; new restrictions are established on the studied Markov variants of continuous spontaneous localization (CSL) and Dieuchy-Penrose (DP) models. For CSL, the limit λ/ < 3.0 × 10⁻³ s⁻¹ m⁻² at the confidence level 90 % was obtained. This form of the limit is applicable for a correlation length rC of no more than approximately 10⁻⁵ m; the conclusion relates to the white noise used and the radiation model adopted. It cannot be transferred to an arbitrary spectrum without recalculation or declared to be the exception of all objective collapses. [16]
The calculation of radiation also depends on the internal structure of the substance. A preprint by Manti et al. for germanium and xenon examined atomic correlations that change the low-energy spectrum of the predicted emission. In the region 1–100 keV, a simple dependence inversely proportional to the photon energy no longer replaces the calculation of a specific material. This is a theoretical refinement of the signal model, not a detection of collapse; To obtain a new numerical limit, it is necessary to reprocess the experimental data. [68]
Such results require discipline in further modeling. A beautiful numerical example with parameters already excluded is acceptable as an educational illustration, if this is clearly indicated. To forecast a real discovery, you need to start with areas that are compatible with the current restrictions in the selected version of the model. Otherwise, high sensitivity appears on paper only because the calculation is looking for an effect, the absence of which has already been shown by another experiment. Checking the available parameter area precedes promises of the power of the new installation.
An experiment as a comparison of explanations
A well-designed test compares multiple explanations of the same entries. The first includes conventional quantum dynamics, medium and apparatus. The second adds a certain change in fundamental dynamics. At the same time, it is useful to consider a third thing: a more complete version of the usual background. If an additional parameter improves the description, this may indicate either a new mechanism or the original model being too poor. A separate plot with small residuals does not allow one to choose between these cases.
Therefore, the experimental program must contain changes in conditions in advance. A decrease in pressure tests one set of assumptions, a change in temperature another, and a redistribution of mass a third. Not every change will be convenient, but physically independent changes are especially valuable. They force the explanation to make new predictions while maintaining the same fundamental parameters. The superposition boundary, if it exists, must appear consistently in such a system of checks. The next chapter specifies which laws can be applied to this requirement.
Compare degrees of freedom and verification methods
The table of experimental platforms is only useful when the same words represent the same measurement tasks. The mass of the vibrational mode, the total mass of the molecule and the mass of the atom in the interferometer refer to different objects of description. For a mode, the effective mass and coordinate amplitude are important; for a molecular beam - the distribution of masses and the history of separation of the center of mass. The internal spin superposition by itself does not determine the difference in spatial mass densities. Therefore, each row of the table begins with a degree of freedom, and not with a record number of atoms.
One published set of MUSCLE measurements is then used as a single numerical reference - the second grating power scan for sodium clusters from April 22 2025. The publication was published in 2026; the date of data recording and the date of the article indicate different events. Information from another mode of the same installation does not replace the parameters of the selected set. This choice allows you to link trajectory calculations, sample processing, and model constraints to a single source. [15, 63]
To compare the types of platforms, it is enough to indicate what test they make possible. The beam interferometer directly tests the spatial interference of transmitted particles. A levitating mechanical object allows for detailed control of movement and heating, but achieving the ground state is not the same as preparing two widely separated branches. Correlated mechanical noise opens up another observation channel and requires its own consideration of geometry. These possibilities complement each other: they should be compared based on the predictions of one selected model. [20, 29]
Platform | Observed value | What is required for the spatial test |
Atomic interferometer | Phase and contrast of the center of mass movement | Separation history, duration, interactions and frequency of events |
Molecules and clusters | Distribution of transmitted particles and fringe harmonics | Mass, shape, velocities, grating photophysics and losses |
Levitating object | Vibrational coordinate, motion spectrum, heating | A certain state of motion; for interference - preparing and bringing together branches |
Related mechanical systems | General and difference correlations | Mass form factor, spacing, mechanical response and common background |
Specification of the selected measurement set
From the original table and program description, the distance between the gratings 0.98375 m, the period 133 nm, the average speed 158 m/s and its Gaussian width 9 m/s are taken. The nominal center of the mass filter is 170 kDa. Weighting the published mass spectrum into the window adopted by the authors gives 168.940 kDa. This number refers to a specific selection rule in the open source. The effective center 172 kDa indicated in the main text of the article refers to its description of the distribution; these numbers should not be silently mixed in the same calculation. Open archive entries are used sequentially to replicate Chapter Twelve. [15, 63]
With these parameters, the de Broglie wavelength is 14.949 fm, and the Talbot wavelength is 1.18327 m. The flight between the first and third gratings lasts 12.4525 ms. This is the evolution time of an individual particle inside the interferometer; it does not coincide with either the second accumulation of counts in one position or with the total duration of the series recording. Separating these three times is necessary to calculate decoherence and statistical error.
In the harmonic description of a symmetric interferometer, the characteristic maximum separation for the first harmonic is hL/(mvd). For the selected inputs it is 110.574 nm. The grating period 133 nm serves as a geometric scale and does not automatically replace this calculated separation. The latter depends on mass and velocity, so in the full calculation the signal is averaged over their distributions. One monochromatic example is useful for checking dimensionality; the final macroscopicity estimate then uses the published averaging.
The radius 4.101 nm in the table is calculated for a homogeneous sphere with a bulk sodium density of 971 kg/m³. It is not an independent measurement of the shape of each particle. Pressures and temperatures are taken from the installation description and supplement to the article. The gas in the chamber is around room temperature, and the internal temperature of the clusters is estimated to be approximately 80 K; substituting one temperature for another would lead to a different estimate of scattering and radiation. [64]
The open table contains 95 scans at 41 position, with a step of 15 nm and a registration time of one second per position. The amount is 3895 seconds, or 64.92 minutes of net accumulation. This value does not include moving, setting up, pumping out or self-calibrations. Registered 10 772 714 counts. The fraction relative to the corresponding reference signals without gratings is 0.13612. This is the relative passage of the entire measuring path, and not the absolute quantum efficiency of the detector.
The last difference shows what the completed specification should be: the number is given along with the procedure for obtaining it and the limits of interpretation. Missing absolute efficiency cannot be recovered by dividing two values if both already contain unknown losses. For mode comparisons, the normalized response may be sufficient; Additional flow and detector measurements will be required to predict the performance of the new facility.
(7.2) is the grating period, L is the distance between adjacent gratings. Index 13 means the span from the first to the third grating; T₁₃ = 12.4525 ms for selected inputs.
(7.3) The first formula specifies the characteristic separation of the first harmonic; the second converts mass into radius at the assumed uniform density ρₘ. These are different geometric characteristics.
Parameter | Meaning | Origin |
Nominal mass | 170 kDa | Mass window in the archive [63] |
mass after weighing | 168.940 kDa | Calculation from published mass spectrum |
Speed and its width | 158 and 9 m/s | Open analysis inputs [63] |
Period and distance | 133 nm; 0.98375 m | Inputs of the same configuration [63] |
Time between G₁ and G₃ | 12.4525 ms | 2L/v |
Chamber pressure | Less than 9 × 10⁻⁹ mbar; in the calculation 9 × 10⁻⁹ | |
Gas/cluster | 300 K / about 80 K | Different physical temperatures [64] |
Sphere size | Radius 4.101 nm | Density 971 kg/m³ - assumption |
Recording capacity | 3895 positions; 10 772 714 counts | Direct file counting [63] |
Net accumulation | 3895 s | Sum of registration times; not full experiment time |
Figure 16. Measuring path of the sodium experiment: neutral clusters pass through three standing ultraviolet waves with a period of 133 nm; after the third grating, ionization, mass filtration and registration are performed. The diagram is functional, not to scale. Specification values refer to the selected published set; The time of flight of a particle differs from the time of accumulation of counters. According to data [63] and description [15].
Constraint Map with Explicit Model
For a spatial test, it is useful to construct a boundary in the plane of intensity λ and length rC. Each point on such a map means a given modification of the dynamics. The same limit of visibility usually gives significantly different restrictions at different lengths: on small scales the structure of the body is significant, on large scales there is poor discrimination of close branches. The map is therefore more informative than the singular number λ for an arbitrarily chosen rC.
As a transparent example, we take a mass-proportional Markov CSL, a homogeneous sphere with specification parameters and the condition of maintaining at least 78% of the reference contrast. The latter value is used in the supplementary material for the interferometric comparison. Here it is transferred to a clearly limited monochromatic setting with the first harmonic and a finite radius. The resulting line is a sensitivity estimate reproduced by formulas, and not a new confidence limit obtained by repeated full processing of all calibrations. [17, 64]
For rC = 100 nm, this formulation gives λ about 7.51 × 10⁻⁹ s⁻¹ at the boundary of the specified condition. The reference mass in normalization is equal to one dalton. The number answers the question what intensity would give an additional attenuation index −ln(0,78) for the chosen trajectory. It does not indicate that such intensity has been detected, nor does it establish the likelihood of a false exclusion.
The same figure shows the published white noise bound XENONnT λ/rC² < 3.0 × 10⁻³ s⁻¹ m⁻² at the confidence level 90%. Its greater rigor in this model does not turn interferometry into an unnecessary experiment: the observation channels test different manifestations of the mechanism and depend on different frequency assumptions. When the spectrum changes, the radiative and interferometric responses must be recalculated. The statistical statuses of the two lines are different and are indicated separately. [16, 24]
It makes sense to design a future protocol in a model space that is still compatible with the relevant constraints. If a training calculation uses a stronger effect for clarity, its amplitude remains a simulation parameter. To claim an achievable fundamental test would require a general model of the spectrum, body, trajectory, and all observables used.
(7.4) K(rC) is calculated by integrating the selected mass kernel along the trajectory. Here Rmin = 0.78 is an explicitly accepted condition for an illustrative line, not an independent level of statistical significance.
Figure 17. Calculated line of condition R ≥ 0.78 for specification geometry and published boundary XENONnT. The first line is illustrative, the second has the declared level 90% CL; both belong to the specified white noise model. These lines cannot be transferred to an arbitrary spectrum. [16, 64]
Comparing platforms becomes meaningful when mass is accompanied by geometry, timing, and registration model. The selected sodium set then goes through media evaluation and re-analysis of the raw readings. This allows each step of the reasoning to be checked and the distinction between the published measurement, the model calibration and the calculated consequence to be maintained.


