brenev.com
РусскийEnglishEspañol日本語한국어
Space from WithinContents

Volume 05 · 20 / 26

Appendix A Mathematical Conventions

Eudgene Brenev (human author) · Mira Veyran (AI coauthor · AI persona) · info@brenev.com

Contents
  1. 01 Front matter
  2. 02 Contents
  3. 03 Preface
  4. 04 How to Read This Book
  5. 05 Chapter 1 Space without an external observer
  6. 06 Chapter 2 How is dimension measured?
  7. 07 Chapter 3 When dimension depends on scale
  8. 08 Chapter 4 Hidden and synthetic directions
  9. 09 Chapter 5 Geometry from quantum relations
  10. 10 Chapter 6 Can space be reconstructed from its response?
  11. 11 Chapter 7 The hypothesis of shared sparse connectivity
  12. 12 Chapter 8 A computational experiment and its robustness
  13. 13 Chapter 9 From a network analogue to a causal physical model
  14. 14 Chapter 10 Hidden Geometry Spectroscopy
  15. 15 Chapter 11 Clocks and gravimeters as a joint probe of space
  16. 16 Chapter 12 What can an interferometer hear?
  17. 17 Chapter 13 Three instruments and the path from signal to inference
  18. 18 Chapter 14 How to distinguish a discovery from a convincing mistake
  19. 19 Chapter 15 What has been established and how to continue testing
  20. 20 Appendix A Mathematical Conventions
  21. 21 Appendix B Repetition of computational experiments
  22. 22 Appendix C A map of testable claims
  23. 23 Appendix D Dictionary of basic concepts
  24. 24 Appendix E Practical work: from voltages to link reconstruction
  25. 25 References
  26. 26 Index of illustrations
Text size

Appendix A
Mathematical Conventions

Symbols and units

The same designation sometimes has different meanings in different areas of physics. In this book, the network operator is denoted by the letter L, and the physical length of the interferometer arm is denoted by the symbol ℒ or by an explicitly named length. The parameter s refers to the Laplace transform; frequency f is measured in hertz, angular frequency ω is equal to 2πf. The diffusion parameter σ in a continuum heat kernel can have the dimension of the square of the length, while the time t in the electrical analogue is measured in seconds. It is impossible to identify them without a normalization coefficient.

Designation

Meaning

Units in the model used

L

Laplacian of a normalized diffusion network

s⁻¹

g

Coupling rate

s⁻¹

G(s)

Normalized response matrix

s

s

Laplace transform parameter

s⁻¹

K

Electrical conductance matrix

siemens

C

Node capacitance or capacitance matrix in an electrical model

farad

R

Compact direction radius

m

qₙ

Inverse spatial mode scale

m⁻¹

q

Potential fluctuation δΦ/c² in the clock model

1

A

RMS field amplitude q in the clock model

1

ℓ and τc

Length and correlation time of the clock pattern

m and s

S(f)

Power Spectral Density

square of signal units per Hz

τ = bᵀG₀b

Coupling-change scalar in Chapter 7; depends on the pair and s

s

C in statistical test

Covariance matrix of measurement errors

square of measured signal units

A₀ = L₀ + sI

Network equation matrix in chapter 7

s⁻¹

σ registration noise

Standard deviation of matrix response errors

s

δₑ and ε

Relative change in weight and the limit of its modulus

1

ηₐ

Known factor of the connection between the general parameter g and probe a

1

aᵀG(s)a

Measuring contrast at normalized a

s

α statistical family

Acceptable probability of going beyond at least one joint boundary for a given noise model

1

α of the Yukawa contribution and β of the mode tower

Relative amplitudes of interactions; are determined separately from statistical α

1

K(t) = exp(−Lt)

Impulse response of a normalized network; different from the electric matrix K

1

HVI(s)

Transfer from current to voltage

ohm

Hφ(f)

Transfer from selected field amplitude to phase

rad per unit field

The graph scalar τ = bᵀG₀b has units of time. Clock q = δΦ/c² is dimensionless. Different values ​​of the letter K are also indicated locally: the electrical matrix of conductances is measured in siemens, and the impulse response K(t) of the normalized network is dimensionless. When moving between chapters, determining the magnitude is more important than matching the letter.

A square matrix acts on a vector of measured quantities. For a voltage network, such a vector contains the voltages of all nodes. The response matrix relates the vector of excitations to the vector of responses for a fixed value of the parameter s. Its diagonal element describes the response at the same node where the impact is applied; off-diagonal - the answer is at another node. The transpose is indicated by the superscript T, and the Hermitian conjugate of a complex matrix is ​​indicated by an asterisk, together with the transpose or † sign according to the context. In real symmetric network models these differences are simplified.

The Frobenius norm of a matrix is equal to the square root of the sum of the squares of the moduli of its elements. Relative error refers to an explicitly specified entity: coupling intensity, response change, or overall response. In the main 64-node experiment, the change in ΔG relative to the standard is analyzed. In the RC workshop, the accuracy of the full G is separately shown, and the connection decision is made by discriminative contrast and model comparison. A small error in the full response may mask a large relative error in the weak additive component.

∥M∥F=∑i,jMij21/2,  εM=∥Mpred-Mtrue∥F∥Mtrue∥F     (A.1)

About probabilities and spectra

A positive Laplacian of a network with non-negative weights of neighboring links generates probability-preserving diffusion. For a finite connected network, the normalized heat trace tends to unity at zero time and to the inverse number of nodes at large times. This means that the spectral dimension calculated from the logarithmic derivative tends to zero at both ends of the range. A possible dimension plateau should be sought between these modes, checking whether it remains the same as the network increases and the resolution changes.

Quantum unitary propagation and ordinary diffusion use different evolution operators. The probability of survival of a quantum state cannot be substituted without inference for the heat trace. Similarly, power spectral density and its square root have different units. For dimensionless strain, the first is measured in Hz⁻¹, and the second in Hz⁻¹ᐟ². Comparing instrument sensitivities also requires the same conventions regarding one-sided or two-sided spectrum, acquisition time, and frequency bandwidth.

Pt=1NTre-tL,  P0=1,  limt→∞Pt=1N     (A.2)

Matrix order and compatibility region

The notation A ≼ B means that vᵀ(B − A)v ≥ 0 for every real vector v. This is the Löwner order on symmetric matrices. For positive-definite matrices, inversion reverses the order. In the network experiment, positive s ensures invertibility even when the Laplacian has a zero mode.

0≺A≼B ⇒ B-1≼A-1     (A.3)

The set of individually acceptable contrasts defines the outer region of possible data. Not every point in this region is generated by one shared conductance vector. Therefore, the remaining candidate receives the status of not being excluded by the shell. The specific feasible set of parameters calculated through the exact forward model provides additional numerical evidence of compatibility.

The χ²/N values in the tables mean the sum of the normalized squares of the residuals per number of records. Here N is not replaced by the number of degrees of freedom after selecting the parameters and choosing the structure. These values ​​are convenient for comparing the scale of the remainder, but in themselves they do not constitute a ready probability of discovery.

Cite this edition