Chapter 11
Clocks and gravimeters as a joint probe of space
One cause and two ways to observe
Two identical instruments can confirm the repeatability of the reading. Two different types of instruments further test the relationship between observed quantities. In a weak quasi-static field, the comparison of clocks is related to the potential difference, and the acceleration of the test body is related to its spatial gradient. Therefore, clocks and gravimeters can be combined to test one cause. This chapter takes the selected statistical model to a joint spectrum, specific geometry, noise budget, and clock-permuted synthetic experiment.
In a weak field, we denote the additional potential by δΦ and introduce the dimensionless quantity q = δΦ/c². For a fixed clock with slow changes and after taking into account known effects, the relative frequency correction between points a and b is approximately equal to the difference q. The sign chosen depends on which frequency ratio is named y_ab; Below we use exactly the definition written in the formula. The gravimetric channel is associated with a negative spatial potential gradient. The actual sensor on the support measures motion relative to its mechanical system, so its response to this quantity needs to be calibrated. The field equation in itself is not yet an equation for the instrument reading. The notation q in this chapter refers only to the dimensionless potential and is not used for the matrix scalar of the network problem.
The ability to measure very small gravitational differences using clocks has been confirmed by individual experiments, but this is not evidence of the proposed additional field. Bothwell and co-authors observed a gravitational frequency gradient within a millimeter-sized atomic sample. Zheng and co-authors performed a blind redshift test on an array of five atomic ensembles with a total height difference of one centimeter. For this chapter, these works provide evidence for the measurement principle and culture of monitoring systematic effects. Their results cannot be translated into ready-made sensitivities of an arbitrary network: other distances, transmission lines, polling intervals and environments will require their own evaluation. [29] [30]
Accelerated clocks in flat spacetime
Before attributing a joint signal to curvature, it is useful to examine a case where it definitely does not exist. Let the system of observers be uniformly accelerated along x. In Rindler coordinates, the interval has the form
For clocks stationary in these coordinates, proper time is dτ = N(x)dt. Comparing them reveals a position-dependent frequency shift. At a₀ = 9.81 m/s² and a short baseline of one meter, the first-order shift is 1.0915 × 10⁻¹⁶. An accelerometer attached to the support also gives a nonzero reading: the observer's proper acceleration is a₀/N(x). Nevertheless, spacetime is flat, as the transformation to inertial coordinates shows directly.
The substitution (11.3) turns the metric into −c²dT² + dX² + dy² + dz², so the entire Riemann tensor is zero. Even the spatial gradient of the readings of accelerated supports should not be directly identified with tidal curvature. For α(x) = a₀/N(x) the exact relation holds
The second term takes into account the kinematics of the selected accelerated system. The relative acceleration of free test bodies in the local inertial frame has a different meaning: after taking into account the initial velocities and the movement of the measuring base, it is related to the tidal components of curvature. In general, a measurement protocol is required that includes observers, signal exchange, and support movement. It is precisely such operational issues that are considered in the works on the clock compass and the relativistic geoid. [41] [42]
The Rindler control specifies a specific requirement for the extended procedure: it must return zero curvature after accounting for system acceleration. Now let's check the same design against a background with a predetermined non-zero tidal component.
Non-zero curvature: clock and tidal gradiometer
Now let's set a background with a non-zero tidal action and draw both measuring channels through it. Let us preserve the static metric with Euclidean spatial sections by adding a quadratic term to the function N. The parameter a₀ has units of acceleration, κ - the reciprocal second squared. The region N > 0 is considered, where both additional terms are small. This is a given local geometric example; the source of its stresses is not derived from Einstein’s equations, and it is not declared a model of the earth’s field.
In order for the sign of curvature to be verifiable, we fix the agreement for the Riemann tensor with the following formula. The coordinate x⁰ is equal to ct. The primes further denote derivatives with respect to x, which here simultaneously measures its own spatial length on a static section.
In the time and x sector, the nonzero connection coefficients are Γ⁰₀ₓ = Γ⁰ₓ₀ = N′/N and Γˣ₀₀ = NN′. Substituting them gives Rˣ₀ₓ₀ = NN″. Going to the orthonormal reference of the stationary observer divides the two time components by N. If α = c²N′/N is the measured proper acceleration of the support along the positive x-axis, the result is conveniently expressed in tidal gradient units:
We will place the static clock at x = 0 and x = ±h. Two extreme sources with the same natural frequency ν₀ send light to a central observer, who compares the received frequencies with his clock. For each ray, the frequency is proportional to −u·k; preserving the covariant time component of the wave vector in the static metric specifies the exact relationship. Therefore, the recorded shifts y± are equal to N(±h) − 1. Their sum removes the linear acceleration term:
The second channel is the difference between the readings of two static accelerometers at the ends of the same base, supplemented by the reading of the central support. Their axes are aligned along x. The finite difference estimates the derivative, and the separately measured squared acceleration removes the kinematic contribution. The resulting value has an independent physical interpretation: free nearby bodies in a non-rotating local inertial frame experience relative tidal acceleration. For positive κ it is compressive. The relationship to measurement frames and the movement of supports is part of the clock compass protocol. [41]
Figure 45 compares the same clock and accelerometric protocol under accelerated flat background and under positive tidal curvature.
Figure 45. The outer atomic clocks transmit light to one central clock; all three stations are supported on supports, and the axes of the accelerometers are directed along +x. Frequency shifts are defined as N(±h) − 1. Their sum removes the linear acceleration term. The acceleration gradient requires a separate central correction α(0)²/c². The lower pairs indicate free test bodies, not clock supports: positive κ gives compression. This is a given local metric; it does not depict the inferred field of the Earth. The finite baseline leaves a calculated correction to the gradient estimate.
Let us choose a₀ = 9.81 m/s², κ = 3 × 10⁻⁶ s⁻² and h = 100 m. Then C₂ = 3.33795 × 10⁻¹⁹, and the central component of curvature is equal to 3.33795 × 10⁻²³ m⁻². The difference in acceleration of the supports is 5.999999998 × 10⁻⁴ m/s². The kinematic correction is equal to 1.07077 × 10⁻¹⁵ s⁻²; after adding it, the estimate κ differs from the given value by −5.01 × 10⁻²⁵ s⁻² due to the finite base. The corresponding free relative acceleration based on 200 m in the local approximation is −6 × 10⁻⁴ m/s².
Let us assign full standard errors after averaging: to each of the three independent clock channels 10⁻²⁰, to each accelerometer 2 × 10⁻⁵ m/s². These are calculation conditions, not stated installation characteristics. The common central clock is included in both frequency differences: their covariance is σ², so the error C₂ is √6 σ rather than 2σ. Frequency transmission is assumed to be calibrated; an unknown additional correlation would require a budget recalculation.
The geometry has two different errors: the standard error of the common half-base is 1 mm, the position of the middle of the outer devices relative to the central one is 10 µm. The latter is especially significant: the displacement of the middle b adds a linear term 2a₀b/c² to C₂. The independent measurement of centering cannot be replaced by the promise of symmetry. Taking these errors into account, the first linear uncertainty transfer gives σ(κ) = 2.2102 × 10⁻⁷ s⁻² for the clock and 1.4142 × 10⁻⁷ s⁻² for the gradiometer. The ratios of the specified signal to these errors are 13.6 and 21.2; this is a notional budget for a fixed configuration.
For the control Rindler at κ = 0 the same clock contrast is exactly zero, as is the local curvature. The finite difference of accelerations leaves only the calculated remainder −1.28 × 10⁻⁴³ s⁻². This means that the protocol distinguishes between an accelerated flat system and a given curved background. The calculation is performed with increased arithmetic precision: the usual subtraction of three numbers around one here loses the clock contrast. This computational precaution does not dictate the accuracy of the clock. Next, we return to the random potential: its joint signal in itself does not replace the tidal control performed here.
Checkable random field pattern
To begin with, it is enough to construct a limited phenomenological hypothesis. Let q have zero mean, equal variance at each point, and spatial correlation decreasing at scale ℓ. Over time, the correlation decays with the characteristic time τ_c. The simplest convenient option combines a Gaussian dependence on distance with an exponential dependence on time shift. Parameter A describes the root-mean-square amplitude q, ℓ is measured in meters, τ_c - in seconds. This choice does not follow from the proven theory of quantum gravity. It specifies a specific test object for which it is possible to derive observed relationships in advance and determine which sensor configurations are the most informative.
The correlation function cannot be chosen only by its beautiful appearance. For any set of points, the matrix of its values must give a non-negative dispersion of any linear combination of signals. Here this condition is satisfied: the spatial Gaussian kernel and the temporal exponential kernel are positive definite, and their product retains the desired property. But probabilistic admissibility does not yet mean physical completeness. It is necessary to explain what dynamics generate the field, how it is connected with matter, and what transformations it is subject to when changing the reference system. A given covariance describes the statistics in the selected observation system and does not by itself determine either the causal response or the transmission rate of the effect.
The limit of long correlation length is especially important. If all the clocks are in a region significantly smaller than ℓ, the field shifts their frequencies almost equally, and the difference measurement suppresses the effect. The network does not become more sensitive to a completely general shift just because its clock is very accurate. In the opposite limit, when the distance is much larger than ℓ, the clocks see almost independent values and the variance of the difference saturates. Hidden between these limits is information about spatial scale. Therefore, different bases are needed, and not a single distance. For the same time band, a variance formula showing both modes immediately follows from the selected kernel.
In Figure 46, the suppression of the difference with a small base is visible on the left, and the time strip of the model is visible on the right. The designation ℓ_c on the horizontal axis of the figure means the same value of ℓ that is used in the text; there is no separate second spatial scale here.
Figure 46. Spatial and temporal parts of the selected covariance. On the left is the variance of the two-clock difference normalized to 2A²; on the right is the normalized Lorentzian spectrum of one q. In the figure, ℓ_c denotes the ℓ used in the text.
One physical interpretation and its limits
The coordinated clock and gravimetric signal may have a common origin. A moving mass creates a potential −GM/|x − x_s(t)|; its difference and gradient will fall into both channels with the same quasi-static coefficients. Therefore, the first physical result of such a network will be an estimate of the general field, and the origin of this field will have to be established separately. Service measurements of pressure, movement of supports and distribution of nearby masses become part of scientific experiment.
For a spatial Gaussian template, a quasi-static Newtonian interpretation can be explicitly constructed. In the chosen system, we set a small density fluctuation around a positive background distribution so that the Poisson equation is satisfied. Then
The spectrum remains positive. In three spatial dimensions, the Gaussian kernel gives the root mean square density c²√15 A/(4πGℓ²). For the numerical example below it is 4.15 kg/m³. The value characterizes the required statistics of the distributed material background in this interpretation, and not the measured density and not proof of its existence. Locally negative δρ means a decrease relative to the background density. Using the Gaussian law remains an approximation of small fluctuations; its infinite tails cannot be taken as a literal model of negative total mass.
Such a field is not a strictly harmonic potential in a region without sources: ∇²q is usually nonzero. The assumption of an ambient vacuum cannot therefore be simultaneously combined with this material explanation without changing the model. For a real background, the laws of motion of matter, conservation of mass, and measurement of its spectrum will also be required. The relation (11.13) completes the static connection between the source and the potential, but does not replace the hydrodynamics or elasticity of the source.
Exponential time covariance corresponds to a process with a kink at zero time shift. It is suitable for a spectral pattern in a limited band, but a full smooth metric at all frequencies would require additional ultraviolet description. Here the operating signals are filtered; When constructing a physical source, the high-frequency spectrum should be smoothly cut off above the experimental band. The conditions 2πfℓ/c ≪ 1 allow the use of a quasi-static approximation. The spatial correlation of noise in itself does not determine the transmission rate of the controlled effect.
In stochastic semiclassical gravity, the random part of the metric response is associated with energy-momentum fluctuations and the Einstein-Langevin equation. This is an example of a deeper dynamical formulation, rather than a deduced origin of the Gaussian kernel chosen here. [43] For this chapter it is enough to fix the reference system, band and status of the potential as a tested effective model.
Spectrum of frequency differences and gradient
In the frequency domain, the chosen time law gives a Lorentzian spectrum. Below, one-sided spectral density is used: the integral over non-negative frequencies is equal to the total dispersion. Therefore, the coefficient 4 in the numerator is due to the normalization convention and not to additional physics. For dimensionless q, the unit of spectral density is the inverse hertz. By denoting the spatial kernel between points i and j by K_ij, one can obtain the mutual spectrum of any two clock comparisons. Its four terms correspond to four pairs of points. The clocks present in both comparisons simultaneously produce common instrumental errors; these errors must be considered separately from the hypothetical field.
The gravimetric prediction is obtained by spatial differentiation of the same kernel. Let r = x − x′. Since the accelerations each contain one derivative, their covariance contains a mixed second derivative with respect to the coordinates of the two points. At zero separation, the root mean square value of one component is c²A/ℓ. On a non-zero basis, covariance depends not only on the distance, but also on the orientation of the component being measured. Longitudinal and transverse channels therefore carry different information. This difference arises from the gradient nature of the field; it should not be added to the fit as an independent arbitrary angular function. Otherwise, the general physical meaning of the two measurements will be lost.
With a small base, the potential difference is approximately equal to the derivative times the distance. This gives us a practical test: the clock signal along the base must correspond to the acceleration projection with a known coefficient d/c² and a chosen sign. This relationship is more useful than the coincidence of two spectral peaks because it captures the relative amplitude. However, it is only valid when d is much smaller than ℓ, the same time filtering and the correct response model of both devices. If one channel was averaged for a minute and the other recorded rapid fluctuations, their total RMS values cannot be directly compared. A simple dimensional check will not correct the misalignment of the measurement bands.
The cross spectrum of two different instruments
Let us introduce S₀(f) = 4A²τ_c/[1 + (2πfτ_c)²] and K(x,z) = exp[−|x − z|²/(2ℓ²)]. Spectral amplitudes are multiplied by exp(−i2πft), and the mutual spectrum is determined by the order S_uv = ⟨ũṽ*⟩. The mixed channel is obtained by one derivative of the same kernel. Since ∂K(x,z)/∂z_i = (x_i − z_i)K/ℓ², the sign of the acceleration is explicitly preserved:
Unit (11.18) - (m/s²)/Hz: the first channel is dimensionless, the second is acceleration. The acceleration autospectrum has a unit of (m/s²)²/Hz. These different dimensions should be preserved when constructing the joint matrix; For numerical inversion, it is convenient to normalize it to the characteristic noise of each channel.
Let us place clock a at x = +d/2, clock b at x = −d/2, and the gravimeter at x = 0. Its positive direction coincides with positive x. Then the negative sign of the cross spectrum means that the positive potential difference directs the acceleration in the opposite direction. The three signal elements of the matrix take a simple form:
This is a consequence of the chosen covariance. As d/ℓ → 0, the coherence tends to unity, but the dispersion of the clock difference simultaneously tends to zero. When d/ℓ ≫ 1 the clock sees almost independent potentials, and the middle gravimeter is weakly coupled to both. Between these limits, you need to choose a base taking into account noise, and not based on one maximum value of γ². At d = ℓ the ideal coherence is equal to 0.98966.
Figure 47. Two clocks and a central gravimeter. The positive direction of acceleration is from b to a. The ideal signal coherence and relative dispersion of the clock channel are shown on the right. High coherence with a small base is accompanied by a small amplitude of the measured difference.
Figure 47 explains why a series of baselines is useful. In the long-wavelength spatial regime, the signal ratio mainly fixes the gradient, and information about the correlation length itself is weak. Measuring near d ≃ ℓ and over a larger base changes the shape of the spectral matrix and helps separate A and ℓ. This is a parameter estimation problem that cannot be solved by simply increasing the time on a near-zero baseline.
A shared measurement band
The theoretical spectrum becomes observable only after passing through the interrogation time window, transmission line, and processing algorithm. The clock can measure the average phase or frequency in individual cycles. The gravimeter has its own sensitivity to frequency, mechanical resonance or a sequence of atomic pulses. Before joint analysis, each channel is associated with a complex transfer function H(f), including amplitude and phase. The transition to the common band is performed taking into account these functions. Frequencies at which the response is poorly known or almost zero cannot be reconstructed by uncontrolled division: such an operation amplifies noise and creates the appearance of structure where the data contains no information.
The quasi-static formula for the frequency difference requires, in particular, that the characteristic time of the field change be significantly longer than the time of light propagation over the base: the product 2πfd/c should be small in the band used. For faster changes, the contribution of the signal path, the movement of the line ends, and the selection of events being compared must be calculated in full. This is not a correction that can automatically be reduced to additional noise. It changes the physical prognosis itself. Even in slow mode, platform movement, height changes, thermal line extension, and residual frequency transmission error are capable of simulating part of the signal. Therefore, time, geometry and calibration must be recorded along with the basic data.
For an ideal rectangular frequency window between f_min and f_max, the variance fraction of the selected Lorentzian process is expressed in terms of the difference in arctangents. This formula is convenient for a preliminary budget: it immediately shows what part of the expected field the device generally observes. If τ_c is very large compared to the duration of the experiment, the process appears to be an almost constant drift. If it is too small compared to the polling interval, most of the power remains out of band and may cause aliasing if not filtered sufficiently. This means that the absence of a visible signal makes sense only in conjunction with the specified range of τ_c and with the data selection model.
A synthetic experiment with common noise and exchanged clocks
Let's consider one completely defined case with known ℓ = 1000 m and τ_c = 10 s. The base is equal to 1000 m, the frequency of the spectral cell is f₀ = 0.01 Hz, the introduced amplitude is A = 10⁻²⁰. The output noise of the clock is given by n_y = 10⁻¹⁸/√Hz, and the noise of the gravimeter is given by n_a = 10⁻⁷ m/s²/√Hz. These values are the input conditions for the calculation. They do not report the constructed network with such precision.
The introduced A corresponds to the total root-mean-square acceleration of one component 8.99 × 10⁻⁷ m/s². It is chosen for computational experiment, and not as an established feasible region of the new cosmological field. The compatibility of such a field with all existing measurements is not stated here. The Newtonian interpretation above shows how strong a material background would accompany this pattern.
The clock frequency is averaged one second with a timestamp in the middle of the window; H_y = sinc(πfT_y), where sinc(z) = sin(z)/z. For the gravimeter, a calibrated single-pole function H_a = 1/(1 − if/f_c) with f_c = 0.1 Hz and the accepted sign of the Fourier amplitudes is selected. The output noise includes a positive overall correlation ρ_n = 0.3. At each frequency the observed matrix is equal to
The interference matrix (11.24) is non-negative definite. Filtering also preserves the positivity of the signal matrix, so complex Gaussian observations can be generated through the Cholesky decomposition of the normalized sum. The program uses seeds 20261113 and 4096 of independent spectral realizations for each configuration. The resulting values are synthetic data with known covariance.
In the second configuration, the clocks are swapped, but the gravimeter and electronic channels are retained. The identities a and b are instrument-specific: the permutation changes the sign of the field S_ya, while the selected total electronic noise remains the same. This interference behavior is a verifiable assumption of the protocol. If the rearrangement changes the electronics themselves or their relationship to vibration, a separate model for that change will be required.
The identity of the clocks, the fixed direction of the gravimeter and the preservation of the electronic channels when rearranged are shown in figure 48.
Figure 48. In the first configuration, clock a is at +d/2, clock b is at −d/2; in the second, only their physical positions change. Electronic comparison preserves the definition y_ab = q_a − q_b, the gravimeter remains in the center and does not change the positive axis. Here K denotes the filtered field cross spectrum. The selected total electronic interference N_ya is considered even with respect to the interference. This is a testable assumption of a particular experiment: the usual spatial gravitational contribution also changes sign and is not automatically excluded.
On average, the odd part contains H_yH_a* S_ya fields, and the even part contains N_ya total noise. Let us put K = H_yH_a* S_ya(A = 1). The estimate of the square amplitude before the non-negativity constraint is Re(K* C_odd)/|K|². A negative value on noise data should be retained when checking the estimate bias, and the boundary A² ≥ 0 should be separately considered when reporting the physical limit.
Magnitude | The result of this calculation |
Ideal signal γ² | 0.98966 |
Observed γ² in the first configuration | 0.001678 |
Injected A² | 1,0000 × 10⁻⁴⁰ |
Recovered A² | 1,2252 × 10⁻⁴⁰ |
Standard error A² given covariance | 1,6575 × 10⁻⁴¹ |
Recovered A | 1,1069 × 10⁻²⁰ |
A² score in a separate experiment with only a common noise | 0.157 standard error from zero |
The drop in observed coherence by almost 590 times shows the role of clock noise. Nevertheless, the accumulation of a given number of independent realizations makes it possible to isolate an odd cross spectrum. The nominal interval A² ± 2σ is [8.94 × 10⁻⁴¹; 1.56 × 10⁻⁴⁰] and contains the entered value. It is calculated with fixed ℓ, τ_c, transfer functions and covariance; adjusting these parameters together will widen the uncertainty.
In the control run, the field is turned off, but the overall interference is retained. The even part gives 3.102 × 10⁻²⁶ (m/s²)/Hz with the expected 3.000 × 10⁻²⁶, and the odd estimate A² deviates from zero only by 0.157 standard error. One such run tests the logic of a given intervention. The frequency of false decisions must be determined in a separate series with new noises and with those classes of common causes that are actually present in the installation.
Figure 49. Synthetic joint experiment. On the left are the expected and obtained real parts of the cross spectrum; the error bars show one standard error given the model. On the right is the expected ratio of an odd field signal to its error when A changes and other parameters remain unchanged.
From the right panel of figure 49, an expected signal to error ratio of five is achieved when A ≈ 8.28 × 10⁻²¹. This is a conditional threshold of sensitivity to a fixed pattern, not a universal significance of the discovery. When A = 10⁻²⁰ the expected ratio is 6.03. If the effective width of an independent spectral cell is equal to 0.001 Hz, a simple estimate T ≈ 2M/Δf gives about 94.8 days for both configurations even before taking into account interruptions. This period immediately places demands on the stability of interference and calibration.
The permutation distinguishes between a field and a specific unchanging electronic connection. The usual spatial gravitational field will change sign along with the hypothetical one. Therefore, experiment establishes the general gradient signal and verifies its statistical form; it does not automatically determine its quantum origin. This requires external source information and additional configurations.
How to separate a field from a common cause in hardware
Two instruments on the same table have many common reasons for correlation. They are combined by reference, power, temperature, reference oscillator and software processing. Even independent meters can respond to one common gravitational disturbance: the movement of mass, a change in pressure, or the redistribution of water. Therefore, the physical network must include service channels and controlled configuration changes. It is useful to move clocks between points, change the length of the base while maintaining some of the electronics, compare different types of clock transitions, and make blind additions of a known signal. Each intervention is selected because the intended field and the specific interference make different predictions for it.
Checking that is done by definition should be avoided. If three relative frequencies are calculated from the same local frequencies, the sum y_ab + y_bc + y_ca is equal to zero algebraically. Successful closure of such a triangle does not confirm the new geometry. It can check the consistency of independent transmission channels, if they are truly independent, but the meaning of the result is then instrumental. Likewise, a high correlation between all pairs is not independent evidence of a universal field: the general error of the standard can create a matrix with the same low rank. Geometric inference requires a response to spatial rearrangements that cannot be reproduced by unchanged general electronics.
The result of a complete physical search must contain the region of valid A, ℓ and τ_c along with the background parameters. The completed example shows the processing of one section of this problem with known ℓ and τ_c. Several bases and frequency bands are needed to restore other parameters; tidal control is needed to infer curvature. If different channels require incompatible parameters, the selected kernel is rejected. If they agree, the next object of study becomes the source of the common field. In the interferometric chapter, the same principle will be applied to a completed light path.