Chapter 12
What can an interferometer hear?
Light measures the completed path
An interferometer compares the phases of light waves that have traveled different paths and then meet again at the detector. It is often depicted as a ruler of extreme precision. For the study of space, such a representation is useful only as a first approximation. The reading depends on the movement of the mirrors, the propagation of light, the phase reference and the reading method. If the theory changes the metric, all of these elements can change in concert. You cannot first declare that space has expanded by a certain amount, and then, without calculation, attribute the same amount to the output of the device. It is necessary to determine which events are compared and which physical phase is returned to the measurement location.
In normal operation, a small change in the difference in arm lengths is associated with a phase shift. For a simple round trip, the coefficient contains 4π/λ_laser, where λ_laser is the laser wavelength. However, this formula applies to specific geometries and low frequencies of mechanical change. In the presence of resonators, light passes through the arm many times, and with fast disturbances, different sections of the path experience different field values. The transfer function acquires frequency zeros and phase delays. Increasing the optical power improves part of the noise budget, but does not restore the physical signal at a frequency to which the selected configuration is insensitive.
Therefore, when designing a geometric probe, the disturbance model is first specified, then the full response is calculated, and only after that the arm length, frequency band and recording method are selected. In some cases, a wide bandwidth is optimal to distinguish the shape of the spectrum. In others, a narrow region of the maximum expected signal is more important. The work of Sharmila, Vermeulen and Datta, published in Nature Communications in 2026, systematically relates several classes of correlations of putative fluctuations to frequency and scale signatures of interferometer output. It confirms the productivity of such a sequence, but does not report the discovery of the quantum structure of space. [33]
Coordinates should not become a signal
The metric of a weakly perturbed space can be written as the sum of the background metric and the small field h_μν. However, the components of h themselves depend on the choice of coordinates. With a small transformation of coordinates, they change to derivatives of the transformation function. If the calculated signal changes only because the researcher has renamed the coordinates, that signal does not match the instrument reading. The calculation must consistently transform light trajectories, mirror world lines, and phase comparison events. The invariant result is a physically defined phase or proper time, and not an arbitrarily chosen component of the disturbance. This requirement is especially important for hypotheses in which the unusual behavior of space is represented by a single scalar function.
A simple example shows how easy it is to get a false forecast. In the long-wavelength approximation, a standard equal-arm interferometer is sensitive to a certain tensor combination of spatial perturbation. If the unit directions of the arms are denoted by u and v, its geometric tensor is equal to half the difference between u_i u_j and v_i v_j. The trace of this tensor is zero. Consequently, the net equal isotropic deformation of spatial lengths is reduced in such a differential combination. This is not a universal prohibition on recording any scalar field: other components of the metric, the movement of mirrors, unequal arms and the finite wavelength require separate calculations. But the automatic identification of scalar noise with the arm difference already turns out to be incorrect.
For the general linear model, it is convenient to represent the output of each sensor as a convolution of the field with the response kernel. This core includes spatial path, delays, polarization sensitivity, and conversion to selected reading units. The cross-spectral density of the sensors is then obtained by applying two such kernels to the field correlation. The schematic notation below highlights the structure of the calculation; it does not replace the specific expression for the chosen theory. Until this expression appears, one cannot claim that the device has achieved sensitivity to amplitude h, since even the relationship between h and the measured voltage may still remain uncertain.
Complete test case with a transverse wave
For the complete calculation, a well-known physical model was chosen: a weak plane transverse traceless gravitational wave in a linear approximation. It provides a strict standard for converting a metric disturbance into phase. Any new hypothesis that reduces in a given strip to the same tensor sector uses the resulting response function; a hypothesis with a different field structure will need its own calculation. The test case itself is not claimed to be a new mechanism of quantum geometry.
Vector n specifies the direction of propagation, e_ij is the selected polarization tensor, h is the dimensionless small amplitude. A simple equal-arm interferometer has arms of length L along the unit vectors u and v. The beam splitter is located at the origin, the distant mirrors are at points Lu and Lv. In a transverse traceless system, freely falling mirrors with zero initial coordinate velocity preserve these coordinates in the first order. The time on the beam splitter coincides with its own time.
The last condition completes the model of movement of the ends. Adding another manually assigned “stretch” to the mirrors fixed here would mean counting the same effect twice. If the mirrors are rigidly held or enter the region of mechanical resonances of the gimbal, their world lines will change and a measured mechanical function must be included in response. Next, we consider the free mass in the operating band above significant mechanical resonances and the optical design without Fabry-Perot cavities.
Let t be the time the light returns to the beam splitter, T = L/c and μ = n·u. From the condition ds² = 0 it follows that the small additional travel time is equal to half the integral h_ij u_i u_j along the unperturbed ray, divided by c. For the round trip path, the field argument values are different:
In the first integral, the photon moves from the beam splitter, and in the second, from the distant mirror. The correction to the trajectory itself inside the already small h does not need to be taken into account in this order: it gives the following order. The two beams are compared after returning to the same event at the beam splitter, so the result refers to the completed measurement. The exact response through the light path time and its difference from the long-wavelength approximation is discussed in detail in the primary work of Rakhmanov, Romano and Whelan. [44]
The closed light path of a simple interferometer and the three events of a single round trip are shown in Figure 50.
Figure 50. In a simple equal-armed Michelson, each ray travels a distance L to the far mirror and L back. The copper and blue sections separate the forward and reverse strokes; in the drawing they are slightly spaced for readability. The right figure captures the departure, reflection, and return of the overall phase comparison event. The conditions for the movement of the mirrors correspond to the free masses in the selected TT model. There are no Fabry-Perot cavities. For an oblique wave, the different field arguments along I₋ and I₊ are preserved in integrals rather than being replaced by a single time.
Frequency and direction enter into the measured response
Let's substitute h(t) = h_ω exp(−iωt). Each integral (12.6) and (12.7) is an integral of an exponential over a finite segment. Let us introduce Ω = ωL/c and sinc(z) = sin(z)/z with a continuous value sinc(0) = 1. Then
Positive phase factors reflect that the field along the path was observed before the light returned; the sign corresponds to the accepted exp(−iωt). As Ω → 0 both factors tend to unity. Let us define the positive phase lag as ω_laser(δT_u − δT_v). The arm difference gives
This takes into account the light path, tensor sensitivity and the selected movement of the mirrors. The function F is dimensionless. With normal incidence on the plane of orthogonal arms and polarization e_xx = 1, e_yy = −1, it reduces to a particularly simple form:
The first zero occurs when different sections of the complete light path cancel each other out. For L = 40 m this is 3.7474 MHz. At this frequency, the chosen normal plane wave does not create a first-order differential phase, although the field itself is non-zero. The tilt changes the phase along the arms, so the zeros and amplitudes of other directions are different. In the program, the normal limit is checked against a general formula; on the calculation grid the discrepancy does not exceed 4.1 × 10⁻¹⁶ in dimensionless amplitude.
The mechanism of the first zero of the transfer function can be seen as the compensation of the full path contributions in Figure 51.
Figure 51. The actual quadrature of the harmonic TT wave is shown at normal incidence and polarization e_xx = 1, e_yy = −1. The phase zero is chosen in the middle of the full path: the integrand is proportional to cos[Ω(t′ − t + T)/T]. At Ω = 0.2 the contributions are almost consistent; at Ω = π, positive and negative areas cancel each other out. The odd quadrature also integrates into zero. Therefore F⊥ = 0 for a non-zero field. This is an exact calculation diagram, not a detector recording; for other directions the zeros change.
If the amplitude h is a stationary random process of one given direction and polarization, its spectrum is converted to S_φ by multiplying by |4πLF/λ_laser|². For the distribution of directions and polarizations, the corresponding integral will be required, and for a pair of installations, the spatial phase between them will also be required. Thus, the calculated answer refers to the precisely named sector of the model; it does not serve as a universal converter of any scalar or "holographic" fluctuation into length noise.
Conditional numerical budget of a simple interferometer
Let's take L = 40 m, laser wavelength 1064 nm, optical power at the input of the reading photodetectors 10 mW and quantum efficiency η = 0.8. For an idealized balanced readout in quadrature, we set the one-sided phase power spectral density of Poisson noise S_φ,shot = 2/Ṅ, where Ṅ = ηP/(hν) is the effective flux of detected photons. Power here refers to the readout and not automatically to the power in the long arms or inside the resonator.
Additionally, we assign independent technical and electronic phase noise 10⁻⁸ and 3 × 10⁻⁹ rad/√Hz. These are conditional constant levels in the band under consideration. Addition in quadrature gives the total phase noise. In a real instrument, the noise may be colored and correlated, and its measured transfer functions will replace these simple constants.
The square root of the power spectral density is called the amplitude spectral density (ASD). For phase noise, its unit is radian per square root of hertz. In the table below, all noise components are reduced to one such value.
Component | Accepted or calculated value |
Effective photon flux | 4.2850 × 10¹⁶ s⁻¹ |
Poisson phase ASD | 6.8318 × 10⁻⁹ rad/√Hz |
Technical phase ASD | 1.0000 × 10⁻⁸ rad/√Hz |
Electronic phase ASD | 3.0000 × 10⁻⁹ rad/√Hz |
Total phase ASD | 1.2477 × 10⁻⁸ rad/√Hz |
Phase coefficient at F = 1 | 4.7242 × 10⁸ rad per unit h |
At the low frequency limit of normal incidence, the equivalent strain noise is 2.6411 × 10⁻¹⁷/√Hz. At 1 MHz it is equal to 2.9778 × 10⁻¹⁷/√Hz, at 3 MHz it is 1.1328 × 10⁻¹⁶/√Hz, and at 10 MHz - 2.5653 × 10⁻¹⁶/√Hz. This is not a measured result from an apparatus. The difference in numbers occurs with constant phase noise only due to the calculated frequency dependence of the response.
Figure 52. Response of a simple 40-meter interferometer to a selected TT polarization. On the left is normal and two oblique directions; on the right is the equivalent strain noise for normal incidence at a given phase budget. The verticals mark geometric zeros. Near zeros, the phase transition in h becomes unstable.
Figure 52 shows why optimization must take into account the form of the hypothesis. Increasing the power reduces the Poisson contribution, but does not remove the geometric zero. Changing the length or direction adds information that is not present in insensitive mode. For a conditional stochastic TT field, the table allows you to specify the spectrum in the band and calculate the expected data; For a new fluctuation mechanism, you first need to check whether its field really belongs to this sector.
A simple budget does not include cavities, radiation pressure, squeezed light and technical losses of a complex optical path. They should be added when choosing the appropriate implementation, preserving the calculated meaning of the phase. Here the task is completed at the selected level: the field, the light path, the freely moving mirrors, the response function and all the numbers of the assigned noise example are connected by one chain.
The correlation must be mathematically valid
A network of interferometers is useful in that a hypothetical field can produce consistent signals, while some of the instruments' own noise is independent. But an arbitrary table of desired correlations does not necessarily describe a possible random process. At each frequency, the spectral matrix must be Hermitian and non-negative definite. For a pair of channels, this follows a familiar restriction: the square of the modulus of the mutual spectrum does not exceed the product of its own spectra. If the model violates this condition, no increase in measurement time will make it physically meaningful. The positivity check must be performed for the entire network matrix, since the validity of individual pairs does not guarantee the validity of the overall population.
To test algorithms, you can use a known valid pattern of output correlations. Let S₀(f) be the non-negative spectral density of some scalar process, and the spatial kernel equal to the exponential minus the square of the distance. Multiplying the kernel by the complex response coefficients R_i and their conjugates retains positivity. This template is useful for blind digital inputs, estimating the separation of independent and total noise, and planning bases. It describes the possible statistics of signals, but does not yet prove that these signals are capable of generating physically consistent fluctuations of the metric. The transition from the template to the gravitational interpretation requires a previous calculation of the light paths.
For the same reason, you cannot assign an additional arbitrary coefficient for each angle and distance and then call a successful fit a discovery of geometry. Rotating the device should change its response according to the general field model. The separation of instruments should change the correlation consistent with the same spatial structure. If rotation simultaneously changes wiring, fiber tension, and cooling conditions, the observed difference is not a pure geometric test. The design of a series of experiments should provide several different interventions: some predominantly change the intended physical response, others - specific instrumental communication pathways. Only a comparison of such series makes it possible to distinguish the causes of the common signal.
What Holometer showed
The Fermilab Holometer was specifically designed to capture rapid, correlated changes in differential position. The description of the 2017 installation shows two adjacent independent interferometers with arms of about 40 meters and correlation reading up to tens of megahertz. The 2021 work used a configuration where one arm of each 39 meter interferometer was bent for sensitivity to specific rotational perturbations. The findings constrained a specific model of spatially consistent rotational fluctuations. These experiments show that an unusual hypothesis can be turned into a testable spectral prediction. They do not mean that any possible quantum properties of space are excluded. [31] [32]
Particular care should be taken when comparing the strain spectral density with the Planck time. Deformation is dimensionless, so its spectral density has the dimension of time; the comparison of units here is correct. But the sensitivity of spectral density is not equal to the instantaneous distance measurement error expressed in meters. To go to dispersion, you need to integrate the spectrum in the specified band and take into account the spatial response. To move to the parameters of the quantum model, additional assumptions about normalization and correlations are required. The phrase about Planck sensitivity without these clarifications easily creates the erroneous impression that the apparatus directly distinguishes individual segments of the Planck length.
The practical lesson is also the limitations of every negative outcome. A configuration that is sensitive to one perturbation symmetry may have little or no response to another. If a theory changes form after each exception, it is necessary to record openly which previous version is rejected and which new assumption is added. For a future program, it is more useful to compose in advance a set of truly different models and calculate the response of each to several configurations. Then the new experiment reduces the explanatory space in a certain way. Without such an account, even high accuracy risks remaining a number that is difficult to translate into knowledge about the structure of space.
QUEST and GQuEST as different measurement strategies
In the first published QUEST series, two benchtop interferometers were used to search for correlated length fluctuations. Patra et al reported limits in the region 13 to 80 megahertz; the accumulation lasted 10⁴ seconds, and the reduced strain sensitivity at 40 megahertz was 3 × 10⁻²⁰ per square root of hertz. The same work indicates the design sensitivity of a separate interferometer 2 × 10⁻¹⁹ meters per square root of hertz over a wider band. These are different quantities with different units and status: the project, the measured result and the result of correlation averaging cannot be replaced with each other. [34]
A separate direction of development for QUEST is related to squeezed light. Bergamin et al., in 2025, examined a source designed for such an application and recorded up to 6.8 decibels of squeezing; no less than 3 decibels remained in the studied band 100 megahertz. These values characterize the specific optical source and measurement procedure. Once incorporated into a large device, some of the benefit may be lost due to optical loss, phase noise, and mode mismatch. Therefore, the source characteristics cannot be automatically recorded in the specification of the finished interferometer. This is an example of step-by-step confirmation: first a component, then a subsystem, then a complete scientific channel. [35]
GQuEST uses a different readout idea: isolating and counting photons associated with a suspected disturbance, instead of the usual detection of a small phase against a background of a strong optical field. The paper 2025 by Vermeulen et al. presents the project being implemented and evaluates its benefit for selected geontropic fluctuation models. This is a study of the project and expected information, not a message about the detection of quantum gravity. The method requires its own assessment of background photons, detection efficiency, filtering and losses. Claiming to overcome the limitations of a particular interferometric sensing method does not mean the elimination of all quantum and technical measurement limitations. [36]
These directions show why you cannot choose a device based on one record number. The correlation scheme, squeezed light and photon counting solve different problems and have different weaknesses. For your own hypothesis, you should calculate the expected output statistics and compare the methods with the same physical signal, time and realistic losses. If one approach produces a narrower band, its gain in amplitude may be accompanied by a loss of information about the shape of the correlation. If the other retains a broad spectrum, it is the waveform that can help distinguish the hypothesis from the background. The criterion becomes the ability to distinguish between explanations, rather than a single sensitivity figure.
The difference between the three operations on the measuring signal is shown in Figure 53.
Figure 53. On the left, two independent interferometric outputs feed into cross-spectrum estimation. At the center, the prepared squeezed light changes the quantum statistics of a single optical input; The symbolic arrows indicate operations rather than a complete map of ports. On the right, optical filtering precedes the detection of individual photons. The principles of the three strategies are shown, not the exact wiring diagrams of Holometer, QUEST or GQuEST. The gain of each approach requires its own estimate of loss, band, background, and output statistics.
Why averaging does not replace control
With independent noise, the average mutual spectrum of two channels tends to zero, and the random error in its estimation decreases with the number of independent samples. In the approximation of a weak signal and Gaussian independent noise, the variance of the real part of the estimate is of the order of the product of the autospectra divided by twice the number of averages. This raises an important distinction: the spectral power threshold improves approximately as the inverse square root of time, while the amplitude spectral density threshold of a stochastic signal improves as the inverse of the fourth root of time. This is not a law for all measurement methods, but a consequence of the specified correlation procedure. Optimal correlation methods and the role of total noise are developed in detail in the work of Allen and Romano. [37]
The general interference does not disappear with such accumulation. On the contrary, its assessment is becoming more accurate, and statistical confidence in the presence of a correlation is growing. Therefore, every promise to improve sensitivity over time must be accompanied by a question about the margin of systematic error. Independent reference oscillators, channel swapping, electrical interference control, optical path-occluded measurements, and deliberate targeting of suspected noise sources are useful. However, no control is universal: blocking the light changes the detector's mode, and rearranging the electronics can leave an overall mechanical connection. Conviction arises from a coherent set of tests selected for specific alternative explanations.
A scientific result requires a map of the output as a function of frequency, length, and configuration. The completed TT example shows how to obtain such a map from the physical field and how to detect blind installation modes even before assembly. Correlation searches test broader statistical models but use the same sequence: computed response, measured noise, and preselected differences between explanations. The next chapter translates this approach into engineering dossiers and a full workshop on an accessible RC network.

![The actual quadrature of the harmonic TT wave is shown at normal incidence and polarization e_xx = 1, e_yy = −1. The phase zero is chosen in the middle of the full path: the integrand is proportional to cos[Ω(t′ − t + T)/T]. At Ω = 0.2 the contributions are almost consistent; at Ω = π, positive and negative areas cancel each other out. The odd quadrature also integrates into zero. Therefore F⊥ = 0 for a non-zero field. This is an exact calculation diagram, not a detector recording; for other directions the zeros change.](/assets/figures/531064bdd94edfac9000e83f.webp)